Medial Longitudinal Arch : Accuracy, Reliability, and Correlation Between Navicular Drop Test and Footprint Parameters.
Title: | Medial Longitudinal Arch : Accuracy, Reliability, and Correlation Between Navicular Drop Test and Footprint Parameters. |
Authors : | Zuil Escobar, Juan Carlos Martín Urrialde, José Antonio Martínez Cepa, Carmen Gómez Conesa, Antonia |
Keywords: | Data Accuracy; Foot; Reproducibility of Results |
Abstract: | Objective: The purpose of this study was to evaluate the correlation among the navicular drop test, the arch angle, the Staheli index and the Chippaux-Smirak index. The reliability and the correlation among the footprint parameters were also estimated. Methods: A cross-sectional study (n = 86; 59.3% women; 27.8 years, standard deviation: 4.8 years) was carried out. The navicular drop test was evaluated and footprint parameters using a plantar pressure platform were recorded in the dominant foot. Pearson correlation coefficients, intraclass correlation coefficient, standard error of measurement, and minimum detectable change were calculated. Results: Both intrarater and interrater reliability were excellent for all the parameters evaluated (intraclass correlation coefficients N 0.880). Statistically significant correlations existed between the navicular drop test and footprints parameters (arch angle = 0,643; Staheli index = 0.633; Chippaux-Smirak index = 0.614). The footprint parameters had excellent correlation with each other (0.838-0.881). The navicular drop test and the footprint parameters studied were reproducible and thus had excellent reliability. Conclusion: The correlations obtained between the navicular drop test and the footprint parameters evaluated were good. The navicular drop test appears to be a reproducible, valid, and simple test for evaluating medial longitudinal arch height, having fewer disadvantages than using footprint parameters. |
Description: | En colaboración con: Carmen B. Martínez-Cepa, Jose A. Martín-Urrialde, Antonia Gómez-Conesa En: Journal of Manipulative and Physiological Therapeutics. e-ISSN 1532-6586 2018, vol 41, n.8, 672-679 |
URI: | http://hdl.handle.net/10637/13125 |
Rights : | http://creativecommons.org/licenses/by-nc-nd/4.0/deed.es |
Issue Date: | 5-Nov-2018 |
Center : | Universidad San Pablo-CEU |