Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/13125
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.creatorZuil Escobar, Juan Carlos-
dc.creatorMartín Urrialde, José Antonio-
dc.creatorMartínez Cepa, Carmen-
dc.creatorGómez Conesa, Antonia-
dc.date2018-
dc.date.accessioned2021-11-05T05:00:21Z-
dc.date.available2021-11-05T05:00:21Z-
dc.date.issued2018-11-05-
dc.identifier000000724510-
dc.identifier.urihttp://hdl.handle.net/10637/13125-
dc.descriptionEn colaboración con: Carmen B. Martínez-Cepa, Jose A. Martín-Urrialde, Antonia Gómez-Conesa-
dc.descriptionEn: Journal of Manipulative and Physiological Therapeutics. e-ISSN 1532-6586 2018, vol 41, n.8, 672-679-
dc.description.abstractObjective: The purpose of this study was to evaluate the correlation among the navicular drop test, the arch angle, the Staheli index and the Chippaux-Smirak index. The reliability and the correlation among the footprint parameters were also estimated. Methods: A cross-sectional study (n = 86; 59.3% women; 27.8 years, standard deviation: 4.8 years) was carried out. The navicular drop test was evaluated and footprint parameters using a plantar pressure platform were recorded in the dominant foot. Pearson correlation coefficients, intraclass correlation coefficient, standard error of measurement, and minimum detectable change were calculated. Results: Both intrarater and interrater reliability were excellent for all the parameters evaluated (intraclass correlation coefficients N 0.880). Statistically significant correlations existed between the navicular drop test and footprints parameters (arch angle = 0,643; Staheli index = 0.633; Chippaux-Smirak index = 0.614). The footprint parameters had excellent correlation with each other (0.838-0.881). The navicular drop test and the footprint parameters studied were reproducible and thus had excellent reliability. Conclusion: The correlations obtained between the navicular drop test and the footprint parameters evaluated were good. The navicular drop test appears to be a reproducible, valid, and simple test for evaluating medial longitudinal arch height, having fewer disadvantages than using footprint parameters.en_EN
dc.formatapplication/pdf-
dc.language.isoen-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es-
dc.subjectData Accuracyen_EN
dc.subjectFooten_EN
dc.subjectReproducibility of Resultsen_EN
dc.titleMedial Longitudinal Arch : Accuracy, Reliability, and Correlation Between Navicular Drop Test and Footprint Parameters.en-En
dc.typeArtículo-
dc.identifier.doihttps://doi.org/10.1016/j.jmpt.2018.04.001-
dc.centroUniversidad San Pablo-CEU-
Aparece en las colecciones: Fisioterapia




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.