Please use this identifier to cite or link to this item: http://hdl.handle.net/10637/14945

Inter and intraexaminer reliability of a new method of infrared thermography analysis of patellar tendon


Thumbnail

See/Open:
 Inter_Molina_QITJ_2021.pdf
780,73 kB
Adobe PDF
Title: Inter and intraexaminer reliability of a new method of infrared thermography analysis of patellar tendon
Other Titles: Reliability of infrared thermography of tendon
Authors : Molina Payá, Francisco Javier
Ríos Díaz, José
Martínez Payá, Jacinto J.
Keywords: Sistema musculoesqueléticoMusculoskeletal systemFisioterapiaPhysical therapyDiagnóstico por imagenDiagnostic imagingTermografíaThermography
Publisher: Informa UK
Citation: Molina Payá, F.J., Ríos Díaz, J. & Martínez Payá, J.J. (2021). Inter and intraexaminer reliability of a new method of infrared thermography analysis of patellar tendon. Quantitative InfraRed Thermography Journal, vol. 18, i. 2, pp. 127-139. DOI: https://doi.org/10.1080/17686733.2019.1700697
Abstract: Thermography is an imaging technique that records the infrared radiation of the skin with a potential to detect asymmetries in body temperature and relating them to pathologies or risk of injury. However, the location of landmarks and region of interest (ROI) can influence the recording process. In this study we describe the reliability of a method to select the ROI without modifying the original thermogram over 68 thermograms (17 participants) of patellar tendon with an infrared camera (softwareOptris 450PI). The width-height, X-Y axis and mean temperature of the ROI was measured by two examiners.All the lower limits of the Intraclass Correlation Coeficiente (CCI) were over 0.84 without biases. The skin temperature was similar for both intra-examiner (F1,33=0.488; p=0.490) and inter-examiner (F1,33=0.011; p=0.917). The mean differences were 0.006ºC (Limit of agreement (LoA): -0.10 to 0.10), The differences between examiners were 0.001 ºC (LoA: -0.13 to 0.13). All temperature differences were <0.25ºC. The method used has very good intra and inter-examiner reliability and reproducibility and the influence on the skin temperature is negligible. It will be of interest to extend the study to ascertain the reliability using different thermal cameras and software, which could increase the strength of the method.
Description: This is an Accepted Manuscript of an article published by Taylor & Francis in "Quantitative InfraRed Thermography Journal" on 17-dec-2019, available at: https://doi.org/10.1080/17686733.2019.1700697
URI: http://hdl.handle.net/10637/14945
ISSN: 1768-6733 (Electrónico)
Issue Date: 2021
Center : Universidad Cardenal Herrera-CEU
Appears in Collections:Dpto. Enfermería y Fisioterapia





Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.