Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/14945
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUCH. Departamento de Enfermería y Fisioterapia-
dc.creatorMolina Payá, Francisco Javier-
dc.creatorRíos Díaz, José-
dc.creatorMartínez Payá, Jacinto J.-
dc.date.accessioned2024-01-18T09:34:30Z-
dc.date.available2024-01-18T09:34:30Z-
dc.date.issued2021-
dc.identifier.citationMolina Payá, F.J., Ríos Díaz, J. & Martínez Payá, J.J. (2021). Inter and intraexaminer reliability of a new method of infrared thermography analysis of patellar tendon. Quantitative InfraRed Thermography Journal, vol. 18, i. 2, pp. 127-139. DOI: https://doi.org/10.1080/17686733.2019.1700697es_ES
dc.identifier.issn1768-6733 (Electrónico)-
dc.identifier.urihttp://hdl.handle.net/10637/14945-
dc.descriptionThis is an Accepted Manuscript of an article published by Taylor & Francis in "Quantitative InfraRed Thermography Journal" on 17-dec-2019, available at: https://doi.org/10.1080/17686733.2019.1700697-
dc.description.abstractThermography is an imaging technique that records the infrared radiation of the skin with a potential to detect asymmetries in body temperature and relating them to pathologies or risk of injury. However, the location of landmarks and region of interest (ROI) can influence the recording process. In this study we describe the reliability of a method to select the ROI without modifying the original thermogram over 68 thermograms (17 participants) of patellar tendon with an infrared camera (softwareOptris 450PI). The width-height, X-Y axis and mean temperature of the ROI was measured by two examiners.All the lower limits of the Intraclass Correlation Coeficiente (CCI) were over 0.84 without biases. The skin temperature was similar for both intra-examiner (F1,33=0.488; p=0.490) and inter-examiner (F1,33=0.011; p=0.917). The mean differences were 0.006ºC (Limit of agreement (LoA): -0.10 to 0.10), The differences between examiners were 0.001 ºC (LoA: -0.13 to 0.13). All temperature differences were <0.25ºC. The method used has very good intra and inter-examiner reliability and reproducibility and the influence on the skin temperature is negligible. It will be of interest to extend the study to ascertain the reliability using different thermal cameras and software, which could increase the strength of the method.es_ES
dc.language.isoenes_ES
dc.publisherInforma UKes_ES
dc.relation.ispartofQuantitative InfraRed Thermography Journal, vol. 18, i. 2-
dc.subjectSistema musculoesquelético-
dc.subjectMusculoskeletal system-
dc.subjectFisioterapia-
dc.subjectPhysical therapy-
dc.subjectDiagnóstico por imagen-
dc.subjectDiagnostic imaging-
dc.subjectTermografía-
dc.subjectThermography-
dc.titleInter and intraexaminer reliability of a new method of infrared thermography analysis of patellar tendones_ES
dc.title.alternativeReliability of infrared thermography of tendon-
dc.typeArtículoes_ES
dc.description.versionPostprint-
dc.identifier.doihttps://doi.org/10.1080/17686733.2019.1700697-
dc.centroUniversidad Cardenal Herrera-CEU-
Aparece en las colecciones: Dpto. Enfermería y Fisioterapia




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.