Airtightness of residential buildings in the Continental area of Spain
dc.centro | Universidad San Pablo-CEU | |
dc.contributor.author | Feijó Muñoz, Jesús | |
dc.contributor.author | Padilla Marcos, Miguel Ángel | |
dc.contributor.author | Meiss, Alberto | |
dc.contributor.author | González Lezcano, Roberto Alonso | |
dc.contributor.other | Universidad San Pablo-CEU. Escuela Politécnica Superior | |
dc.date | 2018 | |
dc.date.accessioned | 2023-09-16T04:00:21Z | |
dc.date.available | 2023-09-16T04:00:21Z | |
dc.date.issued | 2018-12-15 | |
dc.description.abstract | already established standards which aim to limit the energy waste through the envelope following the European Energy Performance of Buildings Directive guidelines. However, in Mediterranean countries there is still a lack of knowledge in this field. An extensive study has been carried out in order to characterize the air leakage through the envelope of the existing housing stock in the Continental climate area of Spain. Results of 129 dwellings tested, including different typologies and periods of construction, are shown. Blower door tests were performed, and thermal imaging was used to locate leakage paths. Single-family dwellings were found to be more airtight than apartments, given that the mean air permeability rate at 50 Pa (q50) was 5.4m3/h·m2 and 6.8m3/h·m2 respectively. The mean air change rate at 50 Pa (n50) was 6.1 h−1 for single-family dwellings and 7.1 h−1 for multi-family housing. Nevertheless, great dispersion of results and extreme values were found. In addition, the influence of several construction characteristics on permeability results was assessed. | en_EN |
dc.format | application/pdf | |
dc.identifier | 000000741554 | |
dc.identifier.citation | Jesús Feijó-Muñoz, Roberto Alonso González-Lezcano, Irene Poza-Casado, Miguel Ángel Padilla-Marcos, Alberto Meiss, Airtightness of residential buildings in the Continental area of Spain, Building and Environment, Volume 148, 2019, Pages 299-308, ISSN 0360-1323, https://doi.org/10.1016/j.buildenv.2018.11.010 | |
dc.identifier.doi | 10.1016/j.buildenv.2018.11.010 | |
dc.identifier.uri | http://hdl.handle.net/10637/14600 | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.relation.ispartof | Building and Environment | |
dc.rights | open access | |
dc.rights.cc | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
dc.subject | Infiltrations | en_EN |
dc.subject | Airtightness | en_EN |
dc.subject | Blower door test | en_EN |
dc.subject | Residential buildings | en_EN |
dc.title | Airtightness of residential buildings in the Continental area of Spain | en_EN |
dc.type | Artículo | |
dspace.entity.type | Publication | es |
relation.isAuthorOfPublication | 0bf10684-dc78-4898-aec0-5037ee0a105e | |
relation.isAuthorOfPublication.latestForDiscovery | 0bf10684-dc78-4898-aec0-5037ee0a105e |
Files
Original bundle
1 - 1 of 1
- Name:
- Airtightness_Feijo_et_al_Buil_Env_2019.pdf
- Size:
- 3.27 MB
- Format:
- Adobe Portable Document Format