Airtightness of residential buildings in the Continental area of Spain

dc.centroUniversidad San Pablo-CEU
dc.contributor.authorFeijó Muñoz, Jesús
dc.contributor.authorPadilla Marcos, Miguel Ángel
dc.contributor.authorMeiss, Alberto
dc.contributor.authorGonzález Lezcano, Roberto Alonso
dc.contributor.otherUniversidad San Pablo-CEU. Escuela Politécnica Superior
dc.date2018
dc.date.accessioned2023-09-16T04:00:21Z
dc.date.available2023-09-16T04:00:21Z
dc.date.issued2018-12-15
dc.description.abstractalready established standards which aim to limit the energy waste through the envelope following the European Energy Performance of Buildings Directive guidelines. However, in Mediterranean countries there is still a lack of knowledge in this field. An extensive study has been carried out in order to characterize the air leakage through the envelope of the existing housing stock in the Continental climate area of Spain. Results of 129 dwellings tested, including different typologies and periods of construction, are shown. Blower door tests were performed, and thermal imaging was used to locate leakage paths. Single-family dwellings were found to be more airtight than apartments, given that the mean air permeability rate at 50 Pa (q50) was 5.4m3/h·m2 and 6.8m3/h·m2 respectively. The mean air change rate at 50 Pa (n50) was 6.1 h−1 for single-family dwellings and 7.1 h−1 for multi-family housing. Nevertheless, great dispersion of results and extreme values were found. In addition, the influence of several construction characteristics on permeability results was assessed.en_EN
dc.formatapplication/pdf
dc.identifier000000741554
dc.identifier.citationJesús Feijó-Muñoz, Roberto Alonso González-Lezcano, Irene Poza-Casado, Miguel Ángel Padilla-Marcos, Alberto Meiss, Airtightness of residential buildings in the Continental area of Spain, Building and Environment, Volume 148, 2019, Pages 299-308, ISSN 0360-1323, https://doi.org/10.1016/j.buildenv.2018.11.010
dc.identifier.doi10.1016/j.buildenv.2018.11.010
dc.identifier.urihttp://hdl.handle.net/10637/14600
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofBuilding and Environment
dc.rightsopen access
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectInfiltrationsen_EN
dc.subjectAirtightnessen_EN
dc.subjectBlower door testen_EN
dc.subjectResidential buildingsen_EN
dc.titleAirtightness of residential buildings in the Continental area of Spainen_EN
dc.typeArtículo
dspace.entity.typePublicationes
relation.isAuthorOfPublication0bf10684-dc78-4898-aec0-5037ee0a105e
relation.isAuthorOfPublication.latestForDiscovery0bf10684-dc78-4898-aec0-5037ee0a105e

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Airtightness_Feijo_et_al_Buil_Env_2019.pdf
Size:
3.27 MB
Format:
Adobe Portable Document Format