Are pathogenic Legionella non-pneumophila a common bacteria in Water Distribution Networks?

dc.centroUniversidad San Pablo-CEU
dc.contributor.authorSalinas Granell, Mireya Beatriz
dc.contributor.authorVaccaro Muñoz, Lucianna Rosalía
dc.contributor.authorValdivieso Blanco, Elizabeth
dc.contributor.authorMagnet, Angela
dc.contributor.authorGomes, Thiago Santos
dc.contributor.authorÁguila de la Puente, Carmen del
dc.contributor.authorHurtado Marcos, Carolina
dc.contributor.authorIzquierdo Arias, Fernando
dc.contributor.authorMagnet Dávila, Angela
dc.contributor.authorOllero Baceiredo, Dolores
dc.contributor.authorPozuelo de Felipe, María José
dc.contributor.authorFenoy Rodríguez, María Soledad
dc.contributor.otherUniversidad San Pablo-CEU. Facultad de Farmacia. Departamento de Ciencias Farmacéuticas y de la Salud
dc.contributor.otherGrupo: Parasitología e Inmunología molecular con aplicación biotecnológica, diagnóstica y terapéutica (PARINM)
dc.date.accessioned2024-01-19T16:49:16Z
dc.date.available2024-01-19T16:49:16Z
dc.date.issued2021-03-07
dc.descriptionAcceso al texto completo en la siguiente URL de la revista: https://www.sciencedirect.com/journal/water-research/vol/196/suppl/C
dc.description.abstractThe present study analyzes at the national level, the presence of circulating Legionella in the artificial aquatic systems of different facilities of all of them state-owned centers throughout Spain for 12 months. 1754 water samples from various state-owned centers were collected from January to December 2014. Samples were collected from the cooling towers and evaporative condensers (CTC), and water distribution networks such as domestic hot water (DHW), cold water for human consumption (CW), sprinkler irrigation systems (SIS), fire sprinkler systems (FSS), and water from decorative fountains (DF). All these facilities are considered, according to current regulations, as potential amplifying systems for bacteria and possible sources of infection by the generation of droplets and aerosols. The isolation and counting of Legionella in water samples was carried out using microbiological culture following the international normative UNE-EN-ISO 11,731:2007 (ISO 11,731:1998) and UNE-EN ISO 8199:2008 (ISO 8199:2005).The quantification of Legionella colonization, the annual distribution, and the geographical distribution of the Legionella isolates recovered in the water were analyzed. Besides, molecular techniques were used for the characterization of the Legionella non-pneumophila isolates. Legionella was recovered from 15.79% of the analyzed water samples. High colonization was more frequently detected in water samples from CTC, DHW, CW, and DF. Regarding the geographic distribution, positive samples of Legionella were obtained in 14 of the 18 Spanish locations analyzed. Legionella non-pneumophila was the most prevalent and was isolated from water samples from 13 different geographical locations (72%). Legionella anisa and Legionella jordanis were the most frequently non-pneumophila species isolated. Legionella donaldsonii was isolated for the first time in the water distribution networks in Spain. Legionella pneumophila sg 2-14 was detected in 13 locations and Legionella pneumophila sg 1 in 11 locations. Therefore, our study concludes that the presence of Legionella pneumophila and Legionella non-pneumophila species in these systems can be a potential threat to public health and should be examined thoroughly with complementary techniques, such as molecular techniques as a screen for routine diagnosis.en_EN
dc.identifier.citationSalinas MB, Fenoy S, Magnet A, Vaccaro L, Gomes TD, Hurtado C, Ollero D, Valdivieso E, Del Águila C, Pozuelo MJ, Izquierdo F. Are pathogenic Legionella non-pneumophila a common bacteria in Water Distribution Networks? Water Res. 2021 May 15;196:117013. doi: 10.1016/j.watres.2021.117013.es_ES
dc.identifier.doi10.1016/j.watres.2021.117013
dc.identifier.issn0043-1354
dc.identifier.urihttp://hdl.handle.net/10637/15034
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofWater Research
dc.rightsrestricted access
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectAir-conditioner cooling towersen_EN
dc.subjectEvaporative cooling systemsen_EN
dc.subjectLegionella non-pneumophilaen_EN
dc.subjectSouth of Europeen_EN
dc.subjectWater facilitiesen_EN
dc.titleAre pathogenic Legionella non-pneumophila a common bacteria in Water Distribution Networks?en_EN
dc.typeArtículoes_ES
dspace.entity.typePublicationes
relation.isAuthorOfPublicationc7b222a9-a1de-4fc8-a5be-ef7a493cc199
relation.isAuthorOfPublication4a4a33ac-98f8-496b-ba87-5ed21614f598
relation.isAuthorOfPublicationf80ba43f-dcca-42ec-b087-33b6d2c46685
relation.isAuthorOfPublicatione719d912-8929-44fb-aa25-417928c894e3
relation.isAuthorOfPublication94151b1a-fd50-4584-9a96-a8f9421f48ce
relation.isAuthorOfPublication0c931cc8-29d4-4876-95b2-5eac5bcbec14
relation.isAuthorOfPublicatione41bb983-e32d-41e9-860f-43b50e82dfd4
relation.isAuthorOfPublicationf25b659d-3778-43b2-9a8a-586114e07d2d
relation.isAuthorOfPublication.latestForDiscoveryc7b222a9-a1de-4fc8-a5be-ef7a493cc199

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Pathogenic_Salinas_et_al_Water_Res_2021.pdf
Size:
1.36 MB
Format:
Adobe Portable Document Format