Escuela de Politécnica Superior
Permanent URI for this collectionhttps://hdl.handle.net/10637/7
Search Results
- Methodology for the Study of the Envelope Airtightness of Residential Buildings in Spain
2018-03-21 Air leakage and its impact on the energy performance of dwellings has been broadly studied in countries with cold climates in Europe, US, and Canada. However, there is a lack of knowledge in this field in Mediterranean countries. Current Spanish building regulations establish ventilation rates based on ideal airtight envelopes, causing problems of over-ventilation and substantial energy losses. The aim of this paper is to develop a methodology that allows the characterization of the envelope of the housing stock in Spain in order to adjust ventilation rates taking into consideration air leakage. A methodology that is easily applicable to other countries that consider studying the airtightness of the envelope and its energetic behaviour improvement is proposed. A statistical sampling method has been established to determine the dwellings to be tested, considering relevant variables concerning airtightness: climate zone, year of construction, and typology. The air leakage rate is determined using a standardized building pressurization technique according to European Standard EN 13829. A representative case study has been presented as an example of the implementation of the designed methodology and results are compared to preliminary values obtained from the database.
- Airtightness of residential buildings in the Continental area of Spain
2018-12-15 already established standards which aim to limit the energy waste through the envelope following the European Energy Performance of Buildings Directive guidelines. However, in Mediterranean countries there is still a lack of knowledge in this field. An extensive study has been carried out in order to characterize the air leakage through the envelope of the existing housing stock in the Continental climate area of Spain. Results of 129 dwellings tested, including different typologies and periods of construction, are shown. Blower door tests were performed, and thermal imaging was used to locate leakage paths. Single-family dwellings were found to be more airtight than apartments, given that the mean air permeability rate at 50 Pa (q50) was 5.4m3/h·m2 and 6.8m3/h·m2 respectively. The mean air change rate at 50 Pa (n50) was 6.1 h−1 for single-family dwellings and 7.1 h−1 for multi-family housing. Nevertheless, great dispersion of results and extreme values were found. In addition, the influence of several construction characteristics on permeability results was assessed.