Escuela de Politécnica Superior

Permanent URI for this collectionhttps://hdl.handle.net/10637/7

Search Results

Now showing 1 - 4 of 4
  • Thumbnail Image
    Publication
    USP
    Assessment of indoor air quality and comfort by comparing an energy simulation and actual data in Native American shelters2023-05-24

    Introduction: This research will determine if a native American shelter (wigwam) can create comfort and if while doing so can provide healthy indoor air quality (IAQ) levels as defined by current standards. Concurrent to this research a technique to digitally model the outcomes of comfort created within the shelter was developed. Methods: A fullsize example of a wigwam was built and data from inside and outside the wigwam monitored for comparison. Data collected both inside and outside was temperature and relative humidity of the air, collected inside the wigwam were CO2, VOC, and PM2.5 levels. The wigwam allowed us to compare the accuracy of a digital model created in Design Builder. The Design Builder model was made to the specific size, materials, and location of the actual wigwam. This allowed an accurate comparison of temperature and relative humidity levels. Design-Builder accurately recreated the attributes of the full-size wigwam. Results and Discussion: It was found that comfort can be achieved to modern standards in this native shelter; as temperature, relative humidity, and rainfall exposure can all be controlled to acceptable levels. Indoor air quality is always at an acceptable level when a fire isn’t active. When an open fire is introduced, the particulates and VOC released into the interior of the wigwam are at dangerous levels. A woodstove with flue pipe allowed for comfort to be maintained at healthier air quality levels but did not reach acceptable levels for particulate matter.

  • Thumbnail Image
    Publication
    USP
    The Relationship between the Use of Building Performance Simulation Tools by Recent Graduate Architects and the Deficiencies in Architectural Education2020-03-03

    This paper examines the actual knowledge regarding Building Performance Simulation Tools (BPSTs) of recent graduate architects in Spain. BPSTs quantify aspects of building performance that are relevant to design, construction, and operation. Recent graduate architects are those who have been awarded a first degree from a university or college and face their first professional experience. This article aims to identify the deficiencies within the current curricula of Spanish universities relating to BPSTs. The authors have surveyed 171 recent graduate architects, and the analysis of the data reveals the deficiencies in university education. Regarding the collected results, the Spanish university syllabi must undergo necessary modifications to encourage the use of simulation as a part of university training courses. The incorporation of energy simulation in such training courses can provide recent graduate architects with tools that would assist them during the design stage. The use of these tools is key in the development of innovative pedagogy-based teaching materials for the courses. In this sense, the present work aims to delve into the usage deficiencies associated with BPSTs and propose ways in which to bridge the gap between higher education and first professional experiences.

  • Thumbnail Image
    Publication
    USP
    Application and Validation of a Dynamic Energy Simulation Tool: A Case Study with Water Flow Glazing Envelope2020-06-19

    The transparent materials used in building envelopes significantly contribute to heating and cooling loads of a building. The use of transparent materials requires to solve issues regarding heat gain, heat loss, and daylight. Water flow glazing (WFG), a disruptive technology, includes glazing as part of the Heating, Ventilation and Air Conditioning (HVAC) system. Water is transparent to visible wavelengths, but it captures most of the infrared solar radiation. As an alternative to fossil fuel-based HVAC systems, the absorbed energy can be transferred to the ground through borehole heat exchangers and dissipated as a means of free-cooling. Researchers of the Polytechnic University of Madrid have developed a software tool to calculate the energy balance while incorporating the dynamic properties of WFG. This article has studied the mathematical model of that tool and validated its ability to predict energy savings in buildings, taking spectral and thermal parameters of glazing catalogs, commercial software, and inputs from the measurements of the prototypes. The results found in this article showed that it is possible to predict the thermal behavior of WFG and the energy savings by comparing the thermal parameters of two prototypes. The energy absorbed by the water depends on the mass flow rate and the inlet and outlet temperatures.

  • Thumbnail Image
    Publication
    USP
    Assessment of Indoor Air Quality in Residential Buildings of New England through Actual Data2022-01-10

    Several studies on indoor air quality (IAQ) and sick building syndromes have been completed over the last decade, especially in cold countries. Efforts to make homes airtight to improve energy efficiency have created buildings with low ventilation rates, resulting in the build-up of indoor pollutants to harmful levels that would be otherwise unacceptable outdoors. This paper analyzed the infiltration rates, indoor temperatures, and variations in CO2, 2.5 m particulate matter (PM2.5), and total volatile organic compound (TVOC) concentrations over the fall of 2021 in several homes in New England, USA. A relationship between outdoor and indoor conditions and ventilation strategies has been set using the results from blower door tests and actual indoor air quality data. Although all case studies lacked mechanical ventilation devices, such as those required by ASHRAE Standard 62.2, natural ventilation and air leakage have been enough to keep VOCs and PM2.5 concentration levels at acceptable values most of the studied time. However, results revealed that 25% of a specific timeframe, the occupants have been exposed to concentration levels of CO2 above 1000 parts per million (ppm), which are considered potentially hazardous conditions.