Please use this identifier to cite or link to this item: http://hdl.handle.net/10637/14447

Determination of cutoff values on computed tomography and magnetic resonance images for the diagnosis of atlantoaxial instability in small-breed dogs


Thumbnail

See/Open:
 Determination_Planchamp_VS_2022.pdf
1,58 MB
Adobe PDF
Title: Determination of cutoff values on computed tomography and magnetic resonance images for the diagnosis of atlantoaxial instability in small-breed dogs
Authors : Planchamp, Bastien
Forterre, Franck
Vidondo Currás, Beatriz
Hernández Guerra, Ángel María
Plessas, Ioannis N.
Schmidt, Martin J.
Keywords: Veterinary diagnostic imaging.Diagnóstico por imagen en veterinaria.Diagnóstico radiológico veterinario.Dogs - Musculoskeletal system.Dogs - Diagnostic imaging.Perros - Sistema musculoesquelético.Perros - Diagnóstico por imagen.
Publisher: John Wiley & Sons
Citation: Planchamp, B., Forterre, F., Vidondo, B., Hernandez-Guerra, A. M., Plessas, I. N., Schmidt, M. J., Waschk, M. A. & Precht, C. (2022). Determination of cutoff values on computed tomography and magnetic resonance images for the diagnosis of atlantoaxial instability in small-breed dogs. Veterinary Surgery, vol. 51, i. 4 (may.), pp. 620–630. DOI: https://doi.org/10.1111/vsu.13799
Abstract: Objective: To determine cutoff values for the diagnosis of atlantoaxial instability (AAI) based on cross-sectional imaging in small-breed dogs. Study design: Retrospective multicenter study. Sample population: Client-owned dogs (n = 123) and 28 cadavers. Methods: Dogs were assigned to three groups: a control group, a “potentially unstable” group, and an AAI-affected group, according to imaging findings and clinical signs. The ventral compression index (VCI), cranial translation ratio (CTR), C1-C2 overlap, C1-C2 angle, atlantoaxial distance, basion-dens interval, dens-to-axis length ratio (DALR), power ratio, and clivus canal angles were measured on CT or T2-weighted magnetic resonance (MR) images. Receiver operating characteristic (ROC) analysis was performed to define cutoff values in flexed (≥25 ) and extended (<25 ) head positions. Results: Cutoff values for the VCI of ≥0.16 in extended and ≥0.2 in flexed head positions were diagnostic for AAI (sensitivity of 100% and 100%, specificity of 94.54% and 96.67%, respectively). Cutoff values for the other measurements were defined with a lower sensitivity (75%-96%) and specificity (70%- 97%). A combination of the measurements did not increase the sensitivity and specificity compared with the VCI as single measurement. Conclusion: Cutoff values for several imaging measurements were established with good sensitivity and specificity. The VCI, defined as the ratio between the ventral and dorsal atlantodental interval, had the highest sensitivity and specificity in both head positions. Clinical significance: The use of defined cutoff values allows an objective diagnosis of AAI in small-breed dogs. The decision for surgical intervention, however, should remain based on a combination of clinical and imaging findings.
Description: Este artículo se encuentra disponible en la siguiente URL: https://onlinelibrary.wiley.com/doi/epdf/10.1111/vsu.13799
En este artículo de investigación también participan: Maja A. Waschk y Christina Precht.
URI: http://hdl.handle.net/10637/14447
Rights : http://creativecommons.org/licenses/by/4.0/deed.es
ISSN: 0161-3499
1532-950X (Electrónico)
Language: es
Issue Date: 16-May-2022
Center : Universidad Cardenal Herrera-CEU
Appears in Collections:Dpto. Medicina y Cirugía Animal





Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.