Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/10777
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUCH. Departamento de Matemáticas, Física y Ciencias Tecnológicas-
dc.contributor.otherProducción Científica UCH 2019-
dc.creatorReal Fernández, Antonio-
dc.creatorNavarro Esbrí, Joaquín-
dc.creatorMota Babiloni, Adrián-
dc.creatorBarragán Cervera, Ángel-
dc.creatorDoménech Ballester, Luis-
dc.creatorSánchez López, Fernando-
dc.creatorMaiorino, Angelo-
dc.creatorAprea, Ciro-
dc.date2019-
dc.date.accessioned2020-03-05T05:00:33Z-
dc.date.available2020-03-05T05:00:33Z-
dc.date.issued2019-09-24-
dc.identifier.citationReal-Fernández, A., Navarro-Esbrí, J., Mota-Baniloni, A, Barragán-Cervera, A., Domenech, L., Sánchez, F. et al. (2019). Modeling of a PCM TES tank used as an alternative heat sink for a water chiller : analysis of performance and energy savings. Energies, vol. 12, n. 19 (24 sep.), art. 3652. DOI: https://doi.org/10.3390/en12193652-
dc.identifier.issn1996-1073 (Electrónico)-
dc.identifier.urihttp://hdl.handle.net/10637/10777-
dc.descriptionEste artículo se encuentra disponible en la página web de la revista en la siguiente URL: https://www.mdpi.com/1996-1073/12/19/3652-
dc.description.abstractPhase change materials (PCMs) can be used in refrigeration systems to redistribute the thermal load. The main advantages of the overall system are a more stable energy performance, energy savings, and the use of the off-peak electric tariff. This paper proposes, models, tests, and analyzes an experimental water vapor compression chiller connected to a PCM thermal energy storage (TES) tank that acts as an alternative heat sink. First, the transient model of the chiller-PCM system is proposed and validated through experimental data directly measured from a test bench where the PCM TES tank is connected to a vapor compression-based chiller. A maximum deviation of 1.2 C has been obtained between the numerical and experimental values of the PCM tank water outlet temperature. Then, the validated chiller-PCM system model is used to quantify (using the coeffcient of performance, COP) and to analyze its energy performance and its dependence on the ambient temperature. Moreover, electrical energy saving curves are calculated for different ambient temperature profiles, reaching values between 5% and 15% taking the experimental system without PCM as a baseline. Finally, the COP of the chiller-PCM system is calculated for di erent temperatures and use scenarios, and it is compared with the COP of a conventional aerothermal chiller to determine the switch ambient temperature values for which the former provides energy savings over the latter.-
dc.formatapplication/pdf-
dc.language.isoen-
dc.publisherMDPI.-
dc.relationEsta publicación recibió financiación de la Agencia Estatal de Investigación (España) a través de una beca postdoctoral del Programa "Juan de la Cierva - Formación 2016" (FJCI-2016-28324).-
dc.relation.ispartofEnergies, vol. 12, n. 19 (24 sep. 2019).-
dc.rightshttp://creativecommons.org/licenses/by/4.0/deed.es-
dc.subjectEnergy conservation.-
dc.subjectIngeniería mecánica.-
dc.subjectMechanical engineering-
dc.subjectTemperature control.-
dc.subjectEnvironmental engineering.-
dc.subjectAhorro energético.-
dc.subjectTemperatura - Control.-
dc.subjectIngeniería ambiental.-
dc.titleModeling of a PCM TES tank used as an alternative heat sink for a water chiller : analysis of performance and energy savings-