Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/10764
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUCH. Departamento de Odontología-
dc.contributor.otherProducción Científica UCH 2019-
dc.creatorMarigo, Luca.-
dc.creatorNocca, Giuseppina.-
dc.creatorFiorenzano, Giulia.-
dc.creatorCallà, Cinzia.-
dc.creatorCastagnola, Raffaella.-
dc.creatorCordaro, Massimo.-
dc.creatorPaolone, Gaetano.-
dc.creatorSauro, Salvatore.-
dc.date2019-
dc.date.accessioned2019-12-17T05:00:49Z-
dc.date.available2019-12-17T05:00:49Z-
dc.date.issued2019-05-09-
dc.identifier.citationMarigo, L., Nocca, G., Fiorenzano, G., Callà, C., Castagnola, R., Cordaro, M. et al. (2019). Influences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials. BioMed Research International, vol. 2019 (9 may), art. 4240264. DOI: https://doi.org/10.1155/2019/4240264-
dc.identifier.issn2314-6133-
dc.identifier.issn2314-6141 (Electrónico)-
dc.identifier.urihttp://hdl.handle.net/10637/10764-
dc.descriptionEste artículo se ha publicado de forma definitiva en: https://www.hindawi.com/journals/bmri/2019/4240264/-
dc.descriptionEn este artículo también participan: Giuseppina Nocca, Giulia Fiorenzano, Cinzia Callà, Raffaella Castagnola, Massimo Cordaro, Gaetano Paolone and Salvatore Sauro.-
dc.description.abstractThe aim of this study was to evaluate the effect of light-curing protocols on two modern resin composites using different airinhibition coating strategies. This was accomplished by assessing the amount of monomer elution, surface microhardness, and composite discoloration in different storage conditions. A total of 120 specimens were prepared using Filtek Supreme XTE (3M ESPE, Seefeld, Germany) and CeramX Universal (Dentsply DeTrey, Konstanz, Germany). Specimens were light-cured in air as per manufacturer’s instructions or in the absence of oxygen. This latter condition was achieved using three different approaches: (i) transparent polyester strip; (ii) glycerin; (iii) argon gas. Specimens were assessed for release of monomers, Vickers hardness, and discoloration after storage in different solutions. The results were analyzed with ANOVA one-way test followed by Student-Newman-Keuls test. Moreover, multiple comparisons of means were performed using the Student t-test (p<0.05). The amount of monomers released from the tested specimens was very low in all conditions. The presence of oxygen induced some decrease in microhardness.The highest discoloration values, for bothmaterials, were obtained after ageing in red wine. In case finish and polish procedures are awkward to achieve in posteriors composite restoration, light-curing in the absence of oxygen should be considered, especially when performing composite restoration in esthetic areas.-
dc.formatapplication/pdf-
dc.language.isoen-
dc.publisherHindawi.-
dc.relation.ispartofBioMed Research International, vol. 2019 (9 may 2019).-
dc.rightshttp://creativecommons.org/licenses/by/4.0/deed.es-
dc.subjectMateriales dentales.-
dc.subjectColor en Odontología.-
dc.subjectColor in dentistry.-
dc.subjectDental materials.-
dc.subjectGums and resins in Dentistry.-
dc.subjectGomas y resinas - Aplicaciones en Odontología.-
dc.titleInfluences of different air-inhibition coatings on monomer release, microhardness, and color stability of two composite materials-
dc.typeArtículo-
dc.identifier.doihttps://doi.org/10.1155/2019/4240264-
dc.centroUniversidad Cardenal Herrera-CEU-
Aparece en las colecciones: Dpto. Odontología




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.