Feasibility of face mask spirometry during decannulation in head and neck surgery prospective cohort study

dc.centroUniversidad Cardenal Herrera-CEU
dc.contributor.authorSánchez Guerrero, José Antonio
dc.contributor.authorCebrià i Iranzo, Maria Àngels
dc.contributor.authorFerrer Sargues, Francisco José
dc.contributor.authorPérié, Sophie
dc.contributor.otherUCH. Departamento de Enfermería y Fisioterapia
dc.contributor.otherProducción Científica UCH 2022
dc.date2022
dc.date.accessioned2023-06-01T04:02:10Z
dc.date.available2023-06-01T04:02:10Z
dc.date.issued2022-07-01
dc.descriptionEste artículo se encuentra disponible en la siguiente URL: https://onlinelibrary.wiley.com/doi/epdf/10.1111/coa.13938
dc.description.abstractObjectives: To analyse the relationship between spirometric parameters measured with a face mask versus a mouthpiece, as well as the feasibility of face mask spirometric evaluation in a head and neck surgery (HNS) decannulation context. Furthermore, we examine peak inspiratory flow (PIF) cut-off values before and after decannulation. Design: Prospective cohort study. Setting: Otolaryngology HNS Department of a university teaching hospital. Participants: Twenty-four patients were selected. A maximal flow-volume loop was conducted before (with mouthpiece) and after (with mouthpiece and face mask) decannulation. Main outcome measures: Recorded outcomes were forced vital capacity (FVC), forced expiratory volume in the first second, peak expiratory flow, PIF, forced expiratory flow at 50% of FVC and forced inspiratory flow at 50% of FVC. Spearman correlation coefficients between spirometric parameters measured with a face mask versus a mouthpiece were calculated. Wilcoxon test was used to check differences between mouthpiece and face mask values. Results: Correlation between mouthpiece and face mask spirometric values was moderate to high (r = 0.46–0.95). All parameters measured by spirometry were significantly lower with a face mask than those obtained with a mouthpiece (p < 0.05). Before decannulation, the lowest PIF value (tested with mouthpiece) that allowed successful decannulation was 1 L/s. After decannulation, the lowest PIF value tested with mouthpiece and face mask for successful completion of the decannulation process were 0.77 and 0.56 L/s, respectively. Conclusion: Face mask is a feasible option to perform a spirometry when face diseases hinder spirometric evaluation through a mouthpiece in an HNC surgery context.
dc.formatapplication/pdf
dc.identifier.citationSánchez-Guerrero, J. A., Cebrià I Iranzo, M. À., Ferrer-Sargues, F. J. & Périé, S. (2022). Feasibility of face mask spirometry during decannulation in head and neck surgery: prospective cohort study. Clinical Otolaryngology, vol. 47, i. 4 (jul.), pp. 521–528. DOI: https://doi.org/10.1111/coa.13938
dc.identifier.doihttps://doi.org/10.1111/coa.13938
dc.identifier.issn1749-4478
dc.identifier.issn1749-4486 (Electrónico)
dc.identifier.urihttp://hdl.handle.net/10637/14384
dc.languagees
dc.language.isoen
dc.publisherJohn Wiley & Sons
dc.relation.ispartofClinical Otolaryngology, vol. 47, i. 4 (jul. 2022)
dc.rightsopen access
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectTraqueotomía.
dc.subjectFace - Surgery.
dc.subjectCuello - Cirugía.
dc.subjectTracheotomy.
dc.subjectSpirometry.
dc.subjectEspirometría.
dc.subjectCara - Cirugía.
dc.subjectNeck - Surgery.
dc.titleFeasibility of face mask spirometry during decannulation in head and neck surgery prospective cohort study
dc.typeArtículo
dspace.entity.typePublicationes
relation.isAuthorOfPublication9a62bda6-eeca-424a-a7ad-31d9e3f55bc4
relation.isAuthorOfPublication2d9d96da-209a-4db4-b9e5-dd38cdd50124
relation.isAuthorOfPublication.latestForDiscovery9a62bda6-eeca-424a-a7ad-31d9e3f55bc4

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Feasibility_Sanchez_CO_2022.pdf
Size:
958.62 KB
Format:
Adobe Portable Document Format