Feasibility of face mask spirometry during decannulation in head and neck surgery prospective cohort study
dc.centro | Universidad Cardenal Herrera-CEU | |
dc.contributor.author | Sánchez Guerrero, José Antonio | |
dc.contributor.author | Cebrià i Iranzo, Maria Àngels | |
dc.contributor.author | Ferrer Sargues, Francisco José | |
dc.contributor.author | Périé, Sophie | |
dc.contributor.other | UCH. Departamento de Enfermería y Fisioterapia | |
dc.contributor.other | Producción Científica UCH 2022 | |
dc.date | 2022 | |
dc.date.accessioned | 2023-06-01T04:02:10Z | |
dc.date.available | 2023-06-01T04:02:10Z | |
dc.date.issued | 2022-07-01 | |
dc.description | Este artículo se encuentra disponible en la siguiente URL: https://onlinelibrary.wiley.com/doi/epdf/10.1111/coa.13938 | |
dc.description.abstract | Objectives: To analyse the relationship between spirometric parameters measured with a face mask versus a mouthpiece, as well as the feasibility of face mask spirometric evaluation in a head and neck surgery (HNS) decannulation context. Furthermore, we examine peak inspiratory flow (PIF) cut-off values before and after decannulation. Design: Prospective cohort study. Setting: Otolaryngology HNS Department of a university teaching hospital. Participants: Twenty-four patients were selected. A maximal flow-volume loop was conducted before (with mouthpiece) and after (with mouthpiece and face mask) decannulation. Main outcome measures: Recorded outcomes were forced vital capacity (FVC), forced expiratory volume in the first second, peak expiratory flow, PIF, forced expiratory flow at 50% of FVC and forced inspiratory flow at 50% of FVC. Spearman correlation coefficients between spirometric parameters measured with a face mask versus a mouthpiece were calculated. Wilcoxon test was used to check differences between mouthpiece and face mask values. Results: Correlation between mouthpiece and face mask spirometric values was moderate to high (r = 0.46–0.95). All parameters measured by spirometry were significantly lower with a face mask than those obtained with a mouthpiece (p < 0.05). Before decannulation, the lowest PIF value (tested with mouthpiece) that allowed successful decannulation was 1 L/s. After decannulation, the lowest PIF value tested with mouthpiece and face mask for successful completion of the decannulation process were 0.77 and 0.56 L/s, respectively. Conclusion: Face mask is a feasible option to perform a spirometry when face diseases hinder spirometric evaluation through a mouthpiece in an HNC surgery context. | |
dc.format | application/pdf | |
dc.identifier.citation | Sánchez-Guerrero, J. A., Cebrià I Iranzo, M. À., Ferrer-Sargues, F. J. & Périé, S. (2022). Feasibility of face mask spirometry during decannulation in head and neck surgery: prospective cohort study. Clinical Otolaryngology, vol. 47, i. 4 (jul.), pp. 521–528. DOI: https://doi.org/10.1111/coa.13938 | |
dc.identifier.doi | https://doi.org/10.1111/coa.13938 | |
dc.identifier.issn | 1749-4478 | |
dc.identifier.issn | 1749-4486 (Electrónico) | |
dc.identifier.uri | http://hdl.handle.net/10637/14384 | |
dc.language | es | |
dc.language.iso | en | |
dc.publisher | John Wiley & Sons | |
dc.relation.ispartof | Clinical Otolaryngology, vol. 47, i. 4 (jul. 2022) | |
dc.rights | open access | |
dc.rights.cc | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
dc.subject | Traqueotomía. | |
dc.subject | Face - Surgery. | |
dc.subject | Cuello - Cirugía. | |
dc.subject | Tracheotomy. | |
dc.subject | Spirometry. | |
dc.subject | Espirometría. | |
dc.subject | Cara - Cirugía. | |
dc.subject | Neck - Surgery. | |
dc.title | Feasibility of face mask spirometry during decannulation in head and neck surgery prospective cohort study | |
dc.type | Artículo | |
dspace.entity.type | Publication | es |
relation.isAuthorOfPublication | 9a62bda6-eeca-424a-a7ad-31d9e3f55bc4 | |
relation.isAuthorOfPublication | 2d9d96da-209a-4db4-b9e5-dd38cdd50124 | |
relation.isAuthorOfPublication.latestForDiscovery | 9a62bda6-eeca-424a-a7ad-31d9e3f55bc4 |
Files
Original bundle
1 - 1 of 1