Experimental evidence reveals both cross-infection and cross-contamination risk of embryo storage in liquid nitrogen biobanks

dc.centroUniversidad Cardenal Herrera-CEU
dc.contributor.authorMontoro Dasí­, Laura
dc.contributor.authorGarcía Domínguez, Ximo
dc.contributor.authorLorenzo Rebenaque, Laura
dc.contributor.authorVicente Antón, José Salvador
dc.contributor.authorMarco Jiménez, Francisco
dc.contributor.authorMarín Orenga, Clara
dc.contributor.otherProducción Científica UCH 2020
dc.contributor.otherUCH. Departamento de Producción y Sanidad Animal, Salud Pública Veterinaria y Ciencia y Tecnología de los Alimentos
dc.date2020
dc.date.accessioned2021-04-28T04:00:38Z
dc.date.available2021-04-28T04:00:38Z
dc.date.issued2020-04-01
dc.descriptionEste artículo se encuentra disponible en la siguiente URL: https://www.mdpi.com/2076-2615/10/4/598
dc.descriptionEste artículo pertenece a la sección "Animal reproduction".
dc.description.abstractIn recent decades, gamete and embryo cryopreservation have become routine procedures in livestock and human assisted reproduction. However, the safe storage of germplasm and the prevention of disease transmission continue to be potential hazards of disease transmission through embryo transfer. This study aimed to demonstrate the potential risk of cross-infection of embryos from contaminated liquid nitrogen, and cross-contamination of sterile liquid nitrogen from infected embryos in naked and closed devices. Additionally, we examined the e ects of antibiotic-free media on culture development of infected embryos. The study was a laboratory-based analysis using rabbit as a model. Two experiments were performed to evaluate both cross-infection (liquid nitrogen to embryos) and cross-contamination (embryos to liquid nitrogen) of artificially inoculated Salmonella Typhimurium, Staphylococcus aureus, Enterobacter aerogenes, and Aspergillus brasiliensis. Rapid cooling through vitrification was conducted on rabbit embryos, stored for a year, thawed, and cultured. In vivo produced late morulae–early blastocyst stages (72 h) embryos were used (n = 480). Embryos were cultured for 1 h in solutions with and without pathogens. Then, the embryos were vitrified and stored in naked and closed devices for one year in two liquid nitrogen biobanks (one pathogen-free and the other artificially contaminated). Embryos were warmed and cultured for a further 48 h, assessing the development and the presence of microorganism (chromogenic media, scanning electron microscopy). Embryos stored in naked devices in artificially contaminated liquid nitrogen became infected (12.5%), while none of the embryos stored in closed devices were infected. Meanwhile, storage of artificially infected embryos incurred liquid nitrogen biobank contamination (100%). Observations by scanning electron microscopy revealed that all the microorganisms were caught in the surface of embryos after the vitrification-thawed procedure. Nevertheless, embryos cultured in antibiotics and antimycotic medium developed to the hatched blastocyst stage, while artificially infected embryos cultured in antibiotic-free medium failed to develop. In conclusion, our findings support that both cross-contamination and cross-infection during embryo storage in liquid nitrogen biobanks are plausible. So, to ensure biosafety for the cryogenic storage, closed systems that avoid direct contact with liquid nitrogen must be used. Moreover, it seems essential to provide best practice guidelines for the cryogenic preservation and storage of gametes and embryos, to define appropriate quality and risk management procedures.
dc.formatapplication/pdf
dc.identifier.citationMarin, C., Garcia-Dominguez, X., Montoro-Dasi, L., Lorenzo-Rebenaque, L., Vicente, J.S. & Marco-Jimenez, F. (2020). Experimental evidence reveals both cross-infection and cross-contamination risk of embryo storage in liquid nitrogen biobanks. Animals, vol. 10, i. 4 (01 apr.), art. 598. DOI: https://doi.org/10.3390/ani10040598
dc.identifier.doihttps://doi.org/10.3390/ani10040598
dc.identifier.issn2076-2615 (Electrónico).
dc.identifier.urihttp://hdl.handle.net/10637/12533
dc.language.isoen
dc.language.isoes
dc.publisherMDPI
dc.relationEste trabajo ha sido financiado por el Ministerio de Economía, Industria y Competitividad (MICINN) del Gobierno de España a través del proyecto AGL2017-85162-C2-1-R.
dc.relationUCH. Financiación Nacional
dc.relation.ispartofAnimals, vol. 10, n. 4.
dc.relation.projectIDAGL2017-85162-C2-1-R
dc.rightsopen access
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectReproductive technologie in animals.
dc.subjectReproducción asistida en los animales.
dc.subjectEmbriología veterinaria.
dc.subjectVeterinary bacteriology.
dc.subjectMicrobiología veterinaria.
dc.subjectVeterinary microbiology.
dc.subjectBacteriología veterinaria.
dc.subjectVeterinary embryology.
dc.titleExperimental evidence reveals both cross-infection and cross-contamination risk of embryo storage in liquid nitrogen biobanks
dc.typeArtículo
dspace.entity.typePublicationes
relation.isAuthorOfPublication10a33a0b-ce7a-480a-a7d2-8bcfc16f5408
relation.isAuthorOfPublication71127598-1cf4-4392-a02a-4bf3783b4d33
relation.isAuthorOfPublication.latestForDiscovery10a33a0b-ce7a-480a-a7d2-8bcfc16f5408

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Experimental_Marin_ANIMALS_2020.pdf
Size:
3.78 MB
Format:
Adobe Portable Document Format