Co-blend application mode of bulk fill composite resin

dc.centroUniversidad Cardenal Herrera-CEU
dc.contributor.authorAl-Nabulsi, Mohammad
dc.contributor.authorSauro, Salvatore
dc.contributor.authorDaud, Alaa
dc.contributor.authorYiu, Cynthia
dc.contributor.authorOmar, Hanan
dc.contributor.authorFawzy, Amr
dc.contributor.authorDaood, Umer
dc.contributor.otherUCH. Departamento de Odontología
dc.contributor.otherProducción Científica UCH 2019
dc.date2019
dc.date.accessioned2020-06-20T04:00:16Z
dc.date.available2020-06-20T04:00:16Z
dc.date.issued2019-08-07
dc.descriptionEste es el artículo que se ha publicado de forma definitiva en: https://www.mdpi.com/1996-1944/12/16/2504
dc.description.abstractObjective:To evaluate the effect of a new application method of bulk-fill flowable compositeresin material on bond-strength, nanoleakage, and mechanical properties of dentine bonding agents.Materials and methods: Sound extracted human molars were randomly divided into: manufacturer ’sinstructions (MI), manual blend 2 mm (MB2), and manual blend 4 mm (MB4). Occlusal enamelwas removed and flattened, dentin surfaces were bonded by Prime & Bond universal (Dentsplyand Optibond FL, Kerr). For the MI group, adhesives were applied following the manufacturer’sinstructions then light-cured. For MB groups, SDR flow+bulk-fill flowable composite resin wasapplied in 2- or 4-mm increment then manually rubbed by a micro brush for 15 s with uncured dentinebonding agents and the mixture was light-cured. Composite buildup was fabricated incrementallyusing Ceram.X One, Dentsply nanohybrid composite resin restorative material. After 24-h waterstorage, the teeth were sectioned to obtain beams of about 0.8 mm2for 24-h and thermocycledmicro-tensile bond strength at 0.5 mm/min crosshead speed. Degree of conversion was evaluatedwith micro-Raman spectroscopy. Contraction gaps at 24 h after polymerization were evaluated andatomic force microscopy (AFM) nano-indentation processes were undertaken for measuring thehardness across the interface. Depth of resin penetration was studied using a scanning electronmicroscope (SEM). Bond strength data was expressed using two-way ANOVA followed by Tukey’stest. Nanoindentation hardness was separately analyzed using one-way ANOVA. Results: Factors“storage F=6.3” and “application F=30.11” significantly affected the bond strength to dentine.For Optibond FL, no significant difference in nanoleakage was found in MI/MB4 groups betweenbaseline and aged specimens; significant difference in nanoleakage score was observed in MB2 groups.Confocal microscopy analysis showed MB2 Optibond FL and Prime & Bond universal specimensdiffusing within the dentine. Contraction gap was significantly reduced in MB2 specimens in bothadhesive systems. Degree of conversion (DC) of the MB2 specimens were numerically more comparedto MS1 in both adhesive systems. Conclusion: Present study suggests that the new co-blend techniquemight have a positive effect on bond strengths of etch-and-rinse adhesives to dentine.
dc.formatapplication/pdf
dc.identifier.citationAl-Nabulsi, M., Daud, A., Yiu, C., Omar, H., Sauro, S., Fawzy, A. et al. (2019). Co-blend application mode of bulk fill composite resin. Materials, vol. 12, n. 16, art. 2504 (7 aug.). DOI: https://doi.org/10.3390/ma12162504
dc.identifier.doihttps://doi.org/10.3390/ma12162504
dc.identifier.issn1996-1944 (Electrónico).
dc.identifier.urihttp://hdl.handle.net/10637/10864
dc.language.isoes
dc.language.isoen
dc.publisherMDPI
dc.relationEste estudio fue financiado por una beca del International Medical University Kuala Lumpur (MU 423/2018).
dc.relation.ispartofMaterials, vol. 12, n. 16.
dc.relation.projectIDMU 423/2018
dc.rightsopen access
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectGums and resins in Dentistry.
dc.subjectGomas y resinas - Aplicaciones en Odontología.
dc.subjectDental materials.
dc.subjectMateriales dentales.
dc.titleCo-blend application mode of bulk fill composite resin
dc.typeArtículo
dspace.entity.typePublicationes
relation.isAuthorOfPublication04e6d781-e677-456e-b56c-ea3fca357bf2
relation.isAuthorOfPublication.latestForDiscovery04e6d781-e677-456e-b56c-ea3fca357bf2

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Co-blend_Al-Nabulsi_Materials_2019.pdf
Size:
2.53 MB
Format:
Adobe Portable Document Format