Facultad de Ciencias de la Salud
Permanent URI for this communityhttps://hdl.handle.net/10637/2790
Search Results
- Efficacy of removing Thermafil and GuttaCore from straight root canal systems using a novel non-surgical root canal re-treatment system : a micro-computed tomography analysis
2021-03-18 The present study aims to evaluate the effectiveness of an XP-endo non-surgical root canal re-treatment system in removing both GuttaCore and Thermafil gutta-percha carrier-based root canal filling materials from straight root canal systems using micro-computed tomography (micro- CT) analysis. The study was performed on 20 single-rooted upper teeth, which were randomly allocated into the following study groups: Group A, Thermafil and AH Plus sealer (n = 10); Group B, GuttaCore and AH Plus sealer (n = 10). Before and after the non-surgical root canal re-treatment procedure, the samples were submitted for a micro-CT analysis. The volume of the root canal filling material (mm3), the volume of the remaining root canal filling material (mm3) and the time (minutes) needed to remove the root canal filling material were also recorded. Student’s t-test was used to analyze the results. No statistically significant differences were found between the volume of the remaining root canal filling material in the GuttaCore and Thermafil root canal filling systems at the coronal third (p = 0.782), middle third (p = 0.838) or apical third (p = 0.882) of the straight root canal systems; however, the GuttaCore required a statistically significant (p = 0.037) shorter amount of time (4.72 0.76 min) to be removed than the Thermafil carrier-based root canal filling material (5.92 1.42 min). The XP-endo Finisher non-surgical endodontic re-treatment system removes both GuttaCore and Thermafil gutta-percha carrier-based root canal filling materials from straight root canal systems, although removal of the GuttaCore gutta-percha carrier-based root canal filling material required less time.
- An 8-year prospective clinical investigation on the survival rate of feldspathic veneers : influence of occlusal splint in patients with bruxism
2020-08-25 Objectives: The aim of this study was to perform a 8-year prospective clinical investigation on the survival rate of feldspathic ceramic veneers, as well as analyse the influence of the occlusal splint in patients with parafunctional bruxism. Methods: Three hundred and sixty-four veneers fabricated using conventional feldspathic ceramic were provided in 64 patients. The patient sample included 40 individuals with bruxism. During the follow-up period, the effect of wearing the occlusal splint on the incidence of failure (fracture and/or debonding) in patients with bruxism was also assessed. The survival rate of veneers was determined using the Kaplan-Meier estimator. Statistical significance was set at p<0.05 with a confidence interval of 95%. Results: The occurrence of fracture for the feldspathic veneers tested in this study was 7.7%, while only 1.9% of the total number of veneers debonded. The overall survival rate was 93.7% after 3 years, 91% after 5 years, and 87.1% after 8 years. Patients with bruxism using an occlusal splint showed a survival rate of 89.1% after 7 years, while the survival rate in patients with bruxism using no occlusal splint was 63.9% (p<0.05). Conclusion: This study confirmed that feldspathic veneers may represent a suitable clinical approach for indirect aesthetic restorations. Such a treatment may be an option also for those patients affected by bruxism, as long as they regularly wear an occlusal splint. However, patients with bruxism using no occlusal splint may still present a potential higher risk of failure and/or debonding.
- Comparison of obturation removal efficiency from straight root canals with ProTaper Gold or Reciproc Bluey : a micro-computed tomography analysis
2020-04-18 Background: The objective was to evaluate the e ciency of ProTaper Gold (PTG) and Reciproc Blue (RB) NiTi files in obturation material removal from straight root canals assessed by micro-computed tomography. Methods: Fifty-two anterior human teeth were shaped with a PTG rotary system until F2 (25/.08). Specimens were obturated with a continuous wave of condensation technique. For retreatment, specimens were randomly distributed in two experimental groups: PTG group (F4 file) and RB (R40 file). Micro-CT scans were performed before and after retreatment procedures. The percentage of the remaining obturation material compared to the original volume was calculated, as well as the retreatment time. The presence of separated files was recorded. A descriptive analysis was carried out, and nonparametric tests were employed. Results: The mean percentages of remaining obturation material in the PTG group and the RB group were 4.14 4.30% and 4.18 4.29%, respectively. The mean retreatment times for the PTG and RB groups were 144 51 and 163 88 s, respectively. There were no statistically significant di erences, neither in removal e ciency (p > 0.05) nor in retreatment time (p > 0.05), between the two groups. The coronal and middle thirds presented significantly more remaining obturation material than the apical third (p < 0.05). No file separation occurred. Conclusions: ProTaper Gold and Reciproc Blue present with comparable e ciency in removing the obturation material, with a similar mean retreatment time.
- The efficacy of rotary, reciprocating, and combined non-surgical endodontic retreatment techniques in removing a carrier-based root canal filling material from straight root canal systems : a micro-computed tomography analysis
2020-06-25 The aim of this study is to analyze and compare the e cacy of three non-surgical endodontic retreatment techniques in removing a carrier-based root canal filling material from straight root canal systems. The study was performed on 99 single-rooted extracted teeth using the ProTaper Gold endodontic rotary system up to the F2 file (Dentsply Maillefer, Baillagues, Switzerland), which were sealed with GuttaCore (Dentsply Maillefer, Ballaigues, Switzerland) and AH plus epoxy resin sealer (Dentsply DeTrey, Konstanz, Germany) and randomly assigned to the following non-surgical retreatment techniques: ProTaper Retreatment endodontic rotary instruments (D1–D3 files, Dentsply Maillefer, Ballaigues, Switzerland; n = 33, PTR), Reciproc Blue endodontic reciprocating instrument (R50, VDW, Munich, Germany; n = 33, RCB50), and a combined root canal retreatment technique between Gates-Glidden drills (sizes #3 and #2, Dentsply Maillefer, Ballaigues, Switzerland) and Hedstrom files (file size 35, 30, and 25, Dentsply Maillefer, Ballaigues, Switzerland; n = 33; H-GG). All of the teeth were submitted twice to a micro-computed tomography (micro-CT) scan, before and after non-surgical endodontic retreatment procedures. The volume of root canal filling material (mm3), volume of remaining root canal filling material (mm3), non-surgical endodontic retreatment working time (min), proportion of remaining root canal filling material (%), and e cacy of root canal filling material removal between the non-surgical endodontic retreatment techniques were analyzed using ANOVA one-way statistical analysis. Statistically significant di erences were observed between the proportions of remaining root canal filling material of PTR and H-GG (p = 0.018), between the non-surgical endodontic retreatment working times (min; p < 0.001), and between the e cacies of root canal filling material removal by the non-surgical endodontic retreatment techniques (p = 0.009). However, the non-surgical endodontic retreatment systems allow for similar carrier-based root canal filling material removal.
- The influence of NiTi alloy on the cyclic fatigue resistance of endodontic files
2020-11-21 Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 m apical diameter, 60 curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All pairwise comparisons presented statistically significant di erences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant di erences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
- Comparative analysis of the smear layer removal capability between EndoVac and Endoactivator endodontic irrigation systems at the root canal system and isthmus: a micro-computed tomography analysis
2020-10-10 The aim of this comparative study is to analyze the e cacy of EndoVac and Endoactivator endodontic irrigation systems for removing the endodontic smear layer present in the coronal, middle, and apical root third of the root canal system (RCS) and the isthmus from mesial roots from the first lower molar teeth using micro-computed tomography (micro-CT) analysis. The study was performed on 40 mesial roots that were randomly assigned to the following groups: Group A, EndoVac endodontic irrigation system (EV) (n = 10); Group B, Endoactivator endodontic irrigation system (EA) (n = 10); Group C, Root canal systems performed with F2 ProTaper Gold endodontic rotary system but not irrigated (Positive control) (n = 10); Group D, Root canal systems not performed or irrigated (Negative control) (n = 10). The samples were exposed to micro-CT analysis and the mesial roots were segmented using an advanced image segmentation technique based on partial di erential equations (ROI: 10 10 10 mm) and the root canal systems and isthmus were reconstructed at a resolution of 25 microns per voxel. The EA study group showed statistically significant di erent residual endodontic smear layer volume (0.48 0.24 mm3) compared to the EV study group (0.18 0.15 mm3) (p = 0.016). The EV endodontic irrigation system performed a higher smear layer removal at coronal and middle root thirds, compared to the EA endodontic irrigation system; however, the EA endodontic irrigation system performed a higher smear layer removal at the apical root third, compared to the EV endodontic irrigation system.