2. Universidad Cardenal Herrera-CEU

Permanent URI for this communityhttps://hdl.handle.net/10637/13

Search Results

Now showing 1 - 2 of 2
  • Thumbnail Image
    Publication
    UCH
    Development and validation of an HPLC-UV method for pazopanib quantification in human plasma and application to patients with cancer in routine clinical practice2015-04

    Background: Pazopanib, a new oral angiogenesis inhibitor, has demonstrated clinical activity against multiple solid tumors and was approved for the treatment of patients with advanced renal cell carcinoma. As an exposure-response relationship has been observed for pazopanib, its therapeutic drug monitoring could be a valuable tool in clinical practice. Therefore, the aim of this study was to develop and validate a selective and precise high performance liquid chromatography-ultraviolet method for the measurement of pazopanib in plasma from patients with cancer. Methods: After liquid-liquid extraction with diethyl ether, pazopanib and gefitinib (internal standard) were separated using isocratic elution on an Ultrabase C18 column using a mobile phase consisting of a mixture in vol/vol proportion of 47:53 of ammonium acetate (pH, 7; 0.02 mol/L) and acetonitrile/methanol (70:30, vol/vol) pumped at a constant flow rate of 1 mL/min. Quantification was performed at 260 nm. Method validation was undertaken as per the guidelines for Bioanalytical Method Validation published by the Food and Drug Administration and European Medicines Agency. Results: Calibration curves were linear over the range 0.5-100 mcg/mL. Interday and intraday coefficients of variations were less than 4.5%. The limit of detection and the lower limit of quantification were 0.2 and 0.5 mcg/mL, respectively. Recovery of pazopanib from plasma was >80%. Conclusions: This is the first high performance liquid chromatography-ultraviolet method for pazopanib quantification that has been validated within a wide range of plasma concentrations and is a suitable method for therapeutic drug monitoring of pazopanib.

  • Thumbnail Image
    Publication
    UCH
    Platelet dynamics in peritoneal carcinomatosis patients treated with cytoreductive surgery and hyperthermic intraperitoneal oxaliplatin2016-01-01

    The aim of the study was to characterize the platelet count (PLT) dynamics in peritoneal carcinomatosis patients treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal oxaliplatin (HIO). Data from patients treated with CRS alone (N = 18) or CRS and HIO (N = 62) were used to estimate the baseline platelet count (PLT0), rate constants for platelet maturation (k tr ) and platelet random destruction (k s ), feedback on progenitor cell proliferation (γ), and the drug-specific model parameters (α, β). Plasma oxaliplatin concentrations, C p , reduced the proliferation rate of progenitor cells (k prol) according to a power function α × C p (β) . The surgery effect on k prol and k s was explored. The typical values (between subject variability) of the PLT0, k tr , k s , γ, α, and β were estimated to be 237 × 10(9) cells/L (32.9%), 7.09 × 10(-3) h(-1) (47.1%), 8.86 × 10(-3) h(-1) (80.0%), 0.621, 0.88 L/mg (56.9%), and 2.63. Surgery induced a maximal 2.09-fold increase in k prol that was attenuated with a half-life of 8.42 days. Splenectomy decreased k s by 47.5%. Age, sex, body surface area, sex, total proteins, and HIO carrier solution did not impact the model parameters. The model developed suggests that, following CRS and HIO, thrombocytopenia and thrombocytosis were reversible and short-lasting; the severity of the thrombocytopenia and thrombocytosis was inversely correlated, with splenectomized patients having thrombocytopenia of lower severity and thrombocytosis of higher severity; and the HIO dose and treatment duration determine the severity and duration of the thrombocytopenia. Higher HIO dose or longer treatment duration could be used without substantially increasing the risk of major hematological toxicity.