2. Universidad Cardenal Herrera-CEU
Permanent URI for this communityhttps://hdl.handle.net/10637/13
Search Results
- An intradialytic non-immersive virtual reality exercise programme: a crossover randomized controlled trial
2022-07 Background: Chronic kidney disease is closely related to a high risk of death and disability, poor physical performance and frailty. The main objective of this research was to analyse how intradialytic administration of a non-immersive virtual reality (VR) exercise programme would affect physical function and adherence to exercise in these patients. Methods: A total of 56 individuals participated in two 12-week periods in a crossover randomized controlled trial. Each patient underwent a functional capacity evaluation before and after each study period. The functional tests administered included the 4-m gait speed test, Short Physical Performance Battery (SPPB), timed up-and-go (TUG) test, one-legged stance test (OLST) for balance, sit-to-stand 10 (STS-10) and sit-to-stand 60 (STS-60) tests and 6-min walking test (6MWT). Adherence to the exercise programme was also recorded. To assess the effect of VR exercise on the functional test outcomes over time, the patients were analysed using a two-way repeated-measures analysis of variance with time and treatment as the within-participant factors. Results: By the end of the 12 weeks of exercise, compared with the control period, 33 participants showed significant change in physical function as measured through the 4-m gait speed test (0.14 m/s), SPPB (1.2 points), TUG (−1.7 s), OLST (7.1 s), STS-10 (−5.8 s), STS-60 (5 repetitions) and 6MWT (85.2 m), with adherence rates exceeding 70%. There were no changes in the biochemical data or in the medications in the period of the study. Conclusion: An intradialytic non-immersive VR exercise programme improves patient physical function.
- Impact of an intradialysis virtual-reality-based exercise program on healthcare resources expenditure a micro-costing analysis
2022-06-27 Background: Engagement in exercise by haemodialysis (HD) patients has been shown to generate benefits both in terms of improved functional capacity and in the health-related quality of life. The use of non-immersive virtual reality (VR) games represents a new format for the implementation of intradialysis exercise. Some studies have shown that engaging in exercise for 6 months reduces the consumption of antihypertensive drugs and decreases the time spent admitted to hospital among individuals receiving HD treatments. The objective of this study was to evaluate changes in the consumption of healthcare resources and micro-costing for patients on HD who completed a VR exercise program. Materials and methods: Design: This study is a secondary analysis of a clinical trial. The participants performed an intradialysis exercise program with non-immersive virtual reality for 3 months. The variables were recorded in two periods: 12 months before and 12 months after the start of the exercise program. Results: The micro-costing analysis showed a significant decrease in the mean cost, in euros, for the consumption of laboratory tests − 330 (95% CI:[− 533, − 126];p = 0.003), outpatient visits − 351 ([− 566, − 135];p = 0.003), and radiology tests − 111 ([− 209, − 10];p = 0.03) in the 12 months after the implementation of the exercise program relative to the 12 months prior to its start. Conclusion: The implementation of intradialysis exercise programs decreased the expenditure of some healthcare resources. Future studies could help clarify if longer interventions would have a stronger impact on these cost reductions.
- Hemodynamic tolerance of virtual reality intradialysis exercise performed during the last 30 minutes versus the beginning of the hemodialysis session
2022-12-27 Background: Exercise improves the physical function of people suffering from chronic kidney disease on hemodialysis (HD). Virtual reality is a new type of intradialysis exercise that has a positive impact on physical function. Intradialysis exercise is recommended during the first 2 h, but its safety in the last part of the dialysis session is unknown. Methods: This was a pilot sub-study of a clinical trial. Several hemodynamic control variables were recorded, including blood pressure, heart rate, and intradialytic hypotensive events. These variables were recorded during three different HD sessions, one HD session at rest, another HD session with exercise during the first two hours, and one HD session with exercise during the last 30 min of dialysis. The intradialysis virtual reality exercise was performed for a maximum of 30 min. Results: During exercise sessions, there was a significant increase in heart rate (6.65 (4.92, 8.39) bpm; p < 0.001) and systolic blood pressure (6.25 (0.04,12.47) mmHg; p < 0.05). There was no difference in hemodynamic control between the sessions with exercise during the first two hours and the sessions with exercise during the last 30 min. There was no association between intra-dialytic hypotensive events at rest (five events) or exercise at any point (two vs. one event(s), respectively). Conclusion: performing exercise with virtual reality at the end of a hemodialysis session is not associated with hemodynamic instability.
- Virtual reality exercise intradialysis to improve physical function : a feasibility randomized trial
2019-01-02 Objective: The main objective of this investigation was to assess feasibility of conducting a future RCT with an intradialysis non-immersive virtual reality exercise intervention. The secondary aim was to explore the impact of either conventional or VR exercise on physical function. Design: Feasibility randomized trial Participants: 18 subjects who participated in a 16 weeks intradialysis combined exercise program. Interventions: The program lasted 4 additional weeks of either combined exercise or virtual reality exercise. Main outcome measures: Physical function was measured through several reliable tests (sit to stand to sit tests 10 and 60, gait speed, one-leg heel rise tests and 6-minute walk test) at baseline, after 16 weeks of intradialysis combined exercise and by the end of 4 additional weeks of exercise. Adherence to the exercise programs was registered. Results: There was a significant time effect, so that physical function improved in both groups. By the end of the 20 weeks, function improved as measured through the sit to stand to sit test 10 and 60, gait speed, one-leg heel rise left leg and the 6-minute walk test. Changes that did not occur due to error in the test were seen after 20 weeks were achieved in the sit to stand to sit test 60, gait speed, one-leg heel rise test for the left leg and 6-minute walking test. Conclusion: Virtual reality was a feasible intervention. Both interventions improved physical function. Adherence was not significantly different between groups.