1. Investigación
Permanent URI for this communityhttps://hdl.handle.net/10637/1
Search Results
- Kinesiophobia and associated variables in patients with heart failure
2023-08-03 Aims: Patients with heart failure (HF) can exhibit kinesiophobia, an excessive, debilitating, and irrational fear of movement. This study aimed to enhance the understanding of kinesiophobia in patients with HF by analysing associations with the following variables: musculoskeletal pain, quality of life, quality of sleep, functional capacity, disability, frailty, sex, and age. Methods and results: In this cross-sectional study, 107 participants were included, with ages ranging from 28 to 97 years (57% men, mean age 73.18 ± 12.68 years). Multiple regression analyses were performed with all variables, including polynomial regressions for variables with a non-linear relationship. Kinesiophobia was significantly correlated (P < 0.01) with musculoskeletal pain, quality of life, quality of sleep, functional capacity, disability, and being at risk of frailty, while age and sex were not statistically significant. Frailty disability and musculoskeletal pain intensity were variables linearly associated with kinesiophobia, while quality of sleep and disability had a non-linear relationship with kinesiophobia. Conclusion: Kinesiophobia needs to be evaluated and better understood in patients with HF to improve physical activity and exercise adherence. This study found that musculoskeletal pain intensity, quality of sleep, disability, and frailty risk have a significant association with kinesiophobia in patients with HF. Our results suggest multi-dimensional associations of kinesiophobia in patients with HF, which require further examination and understanding.
- Blood flow effects of percutaneous peripheral nerve stimulation: a blinded, randomized clinical trial
2024-01 Background: The vasculature function is mainly regulated by the autonomic nervous system. Importantly, the sensory-motor nervous system also innervates peripheral vessels and has the capacity to modulate vascular tone. Here we investigated the effects of electrical stimulation of a mixed nerve trunk on blood flow in deep arteries and muscle perfusion. Our hypothesis is that stimulation of a mixed nerve can modify blood flow. Methods: Twenty-nine healthy participants were included into a randomized-crossover and blinded clinical trial. Each subject received a placebo and two percutaneous peripheral nerve stimulation (pPNS) protocols on the median nerve: Pain Threshold continuous Low Frequency (PT-cLF) and Sensory Threshold burst High Frequency (ST-bHF). Blood flow was then assessed bilaterally using Power Doppler Ultrasonography at the main arteries of the arm, and blood perfusion at the forearm muscles. Afterwards, blood flow was quantified using a semi-automatized software, freely shared here. Results: Placebo, consisting in needle insertion, produced an immediate and generalized reduction on peak systolic velocity in all arteries. Although nerve stimulation produced mainly no effects, some significant differences were found: both protocols increased the relative perfusion area of the forearm muscles, the ST-bHF protocol prevented the reduction in peak systolic velocity and TAMEAN of the radial artery produced by the control protocol and PT-cLF produced a TAMEAN reduction of the ulnar artery. Conclusions: Therefore, the arterial blood flow in the arm is mainly impervious to the electrical stimulation of the median nerve, composed by autonomic and sensory-motor axons, although it produces mild modifications in the forearm muscles perfusion.
- Infrared thermography, intratendon vascular resistance, and echotexture in athletes with patellar tendinopathy: a cross-sectional study
2023-02-13 Ultrasonographic signs of tendinopathies are an increase in thickness, loss of alignment in collagen fibers and the presence of neovascularization. Nevertheless, analysis of intratendinous vascular resistance (IVR) can be more useful for understanding the physiological state of the tissue. To show thermal, echotextural, and Doppler signal differences in athletes with patellar tendinopathy and controls. Twenty-six athletes with patellar tendinopathy (PT) participants (30.1 years; SD = 9.0 years) and 27 asymptomatic athletes (23.3 years; SD = 5.38 years) were evaluated with thermographic and Doppler ultrasonography (DS). Area of Doppler signals (DS), echotextural parameters (echointensity and echovariation) and IVR were determined by image analysis. The statistical analysis was performed by Bayesian methods and the results were showed by Bayes Factor (BF10: probability of alternative hypothesis over null hypothesis), and Credibility intervals (CrI) of the effect. The absolute differences of temperature (TD) were clearly greater (BF10 = 19) in the tendinopathy group (patients) than in controls. Regarding temperature differences between the affected and healthy limb, strong evidence was found (BF10 = 14) for a higher temperature (effect = 0.53°C; 95% CrI = 0.15°C–0.95°C) and very strong for reduced IVR compared (BF10 = 71) (effect = −0.67; 95% CrI = −1.10 to 0.25). The differences in area of DS (BF10 = 266) and EV (BF10 = 266) were higher in tendinopathy group. TD showed a moderate positive correlation with VISA-P scores (tau-B = .29; 95% CrI = .04–.51) and strong correlation with IVR (r = −.553; 95%CrI = −.75 to .18). Athletes with patellar tendinopathy showed a more pronounced thermal difference, a larger area of Doppler signal, a lower IVR and a moderately higher echovariaton than controls. The correlation between temperature changes and IVR might be related with the coexistence of degenerative and inflammatory process in PT.
- Inter and intraexaminer reliability of a new method of infrared thermography analysis of patellar tendon
2021 Thermography is an imaging technique that records the infrared radiation of the skin with a potential to detect asymmetries in body temperature and relating them to pathologies or risk of injury. However, the location of landmarks and region of interest (ROI) can influence the recording process. In this study we describe the reliability of a method to select the ROI without modifying the original thermogram over 68 thermograms (17 participants) of patellar tendon with an infrared camera (softwareOptris 450PI). The width-height, X-Y axis and mean temperature of the ROI was measured by two examiners.All the lower limits of the Intraclass Correlation Coeficiente (CCI) were over 0.84 without biases. The skin temperature was similar for both intra-examiner (F1,33=0.488; p=0.490) and inter-examiner (F1,33=0.011; p=0.917). The mean differences were 0.006ºC (Limit of agreement (LoA): -0.10 to 0.10), The differences between examiners were 0.001 ºC (LoA: -0.13 to 0.13). All temperature differences were <0.25ºC. The method used has very good intra and inter-examiner reliability and reproducibility and the influence on the skin temperature is negligible. It will be of interest to extend the study to ascertain the reliability using different thermal cameras and software, which could increase the strength of the method.
- Reliability of a new semi-automatic image analysis method for evaluating the Doppler signal and intratendinous vascular resistance in patellar tendinopathy
2021-12 The aim of this study was to determine the intra- and inter-rater reliability of a new semi-automatic image analysis method for quantification of the shape of the Doppler signal and the intratendinous vascular resistance in patellar tendinopathy. Thirty athletes (27.4 y, standard deviation = 8.57 y) with patellar intratendinous vascularity were included in a cross-sectional study (42 tendons analyzed). The intratendinous blood flow was assessed with power Doppler and ImageJ (Version 1.50b, National Institutes of Health, Bethesda, MD, USA) quantification software over a manually selected region of interest. Two blinded observers performed the analysis of the Doppler signal (vascular resistance) and shape descriptors (number of signals, pixel intensity, area, perimeter, major diameter, minor diameter, circularity and solidity). The intraclass correlation coefficient (ICC) was calculated, and the Bland-Altman mean of differences (MoD) and 95% limits of agreement (LoA) were determined. Also, small real differences (SRDs) and the standard error of measurement (SEM) were calculated. Intra-rater reliability was at a maximum for area (ICC = 0.999, 95% confidence interval [CI] = 0.998-0.999) and at a minimum for solidity (ICC = 0.782, 95% CI: 0.682-0.853). The MoD and 95% LoA were very low, and the relative SRD and SEM were below 5.3% and 2%, respectively. The inter-rater reliability was the maximum for area (ICC = 0.993, 95% CI = 0.989-0.996) and the minimum for circularity (ICC = 0.73; 95% CI=0.611-0.817). The MoD and 95% LoA were low, with the SRD and SEM below 6% and 2.2%. The proposed quantitative method for studying the intratendinous Doppler signal in the patellar tendon is reliable and reproducible.
- Validation of new semi-automated ultrasound image analysis method for assessing vascular resistance in musculoskeletal tissues
2023-01 Objective: The aim of this study was to analyze the concurrent validation between the resistance index (RI) obtained by Spectral Doppler (SD) and the vascular resistance (VR) calculated by quantifying pixel color intensity of the power Doppler (PD) signal. Methods: The brachial artery of 30 healthy participants (24.8 yrs; SD = 6.44 yrs) were evaluated with systolic and diastolic peaks. Three assessments were performed on each participant, obtaining a total of 90 ultrasound assessments of the brachial artery with their respective RI. Processing and analysis were performed ImageJ software were manually selected and extracted from the brachial artery PD images with the highest and lowest signal corresponding to peak systolic and end diastole for each patient. The mean pixel color of the image with the highest signal was considered as the peak systolic velocity and of the image with the lowest signal as the end-diastolic velocity. Results: A high correlation was found between RI and VR (r=.92; 95%CI= .88 to .95; p there is a very strong concurrent validity between the two measures, and they can be considered equivalents (common variability of 84%). Conclusion: This new method of analyzing DS by quantifying the color intensity of the PD signal pixel is a good predictor of RI and could be useful for VR analysis in musculoskeletal tissues where measurement of RI is complicated such in neovascularization in tendinopathies with multiple Doppler signals.