Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10637/5624
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor | Universidad San Pablo-CEU. Escuela Politécnica Superior | es |
dc.creator | Parras Simón, Javier | es |
dc.date | 2013 | es |
dc.date.accessioned | 2013-11-28T05:00:24Z | - |
dc.date.available | 2013-11-28T05:00:24Z | - |
dc.date.issued | 2013-11-28T05:00:24Z | - |
dc.identifier | 000000582194 | es |
dc.identifier.uri | http://hdl.handle.net/10637/5624 | - |
dc.description | Tesis-Universidad CEU San Pablo, Escuela Politécnica Superior, [638 pags], 26 noviembre 2013 | es |
dc.description.abstract | Analiza como la variación de la conductividad térmica de los materiales de protección al fuego de estructuras metálicas durante un incendio influye en la temperatura que va alcanzando el elemento estructural. En la reglamentación nacional se ofrecen valores constantes de este parámetro (usualmente a temperatura ambiente) que, como se trata de demostrar, no corresponden con el comportamiento real del mismo. Con tal objetivo, se ha centrado el análisis en las placas de yeso laminado investigando diversos estudios internacionales y resultados de ensayos realizados, de acuerdo con la Norma ENV 13381-4, por distribuidores nacionales de este tipo de material. Para completar el estudio se han realizado diversos ensayos a pequeña escala de probetas de acero laminado revestidas de placas de yeso laminado en horno eléctrico y, a partir de los resultados obtenidos, se realiza una propuesta simplificada de valores de conductividad térmica efectiva para ser utilizados en los procedimientos analíticos de cálculo que determinan el espesor de material protección necesario. | es |
dc.description.abstract | Analyzes how the variation of the thermal conductivity of the fire protection materials of metal structures during a fire influences the temperature that the structural element reaches. In the national regulations constant values of this parameter are offered (usually at room temperature) that, as it is tried to demonstrate, do not correspond to the real behavior of the same. To this end, the analysis of laminated gypsum boards has focused on investigating various international studies and test results carried out, in accordance with the ENV 13381-4 Standard, by national distributors of this type of material. In order to complete the study, various small-scale tests have been carried out on rolled steel specimens covered with gypsum plates rolled in an electric oven and, based on the results obtained, a simplified proposal of effective thermal conductivity values is made to be used in analytical calculation procedures that determine the thickness of the necessary protective material. | en |
dc.format | application/pdf | es |
dc.language.iso | sp | es |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | es |
dc.subject | Construcciones metálicas. | es |
dc.subject | Transmisión del calor en la edificación | es |
dc.subject | Metal constructions. | en |
dc.subject | Heat transmission in buildings. | en |
dc.title | Variación de la conductividad térmica efectiva de materiales de protección al fuego de estructuras metálicas de alta temperatura. | es |
dc.type | Tesis | es |
europeana.dataProvider | UNIVERSIDAD SAN PABLO CEU | - |
europeana.isShownAt | http://hdl.handle.net/10637/5624 | - |
europeana.object | http://repositorioinstitucional.ceu.es/visor/libros/582194/thumb_europeana/582194.jpg | - |
europeana.provider | Hispana | - |
europeana.rights | http://creativecommons.org/publicdomain/zero/1.0/ | - |
europeana.type | TEXT | - |
dc.contributor.director | Isidro Gordejuela, Federico de | es |
dc.centro | Universidad San Pablo-CEU | - |
Aparece en las colecciones: | Escuela de Politécnica Superior |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.