Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/15968
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUniversidad San Pablo-CEU. Facultad de Farmacia-
dc.contributor.otherGrupo: Biotecnología de la Interacción Planta-Microbioma (PLANTA-MICROBIOMA)-
dc.creatorGrijalbo Fernández, Lucía-
dc.creatorBecerril, J.M.-
dc.creatorBarrutia, O.-
dc.creatorGutiérrez Mañero, Francisco Javier-
dc.creatorLucas García, José Antonio-
dc.date.accessioned2024-06-20T12:43:46Z-
dc.date.available2024-06-20T12:43:46Z-
dc.date.issued2016-03-23-
dc.identifier.citationGrijalbo L, Becerril JM, Barrutia O, Gutierrez-Mañero J, Lucas Garcia JA. Lemna minor tolerance to metal-working fluid residues: implications for rhizoremediation. Plant Biol (Stuttg). 2016;18(4):695-702. doi:10.1111/plb.12454en_EN
dc.identifier.issn1435-8603-
dc.identifier.urihttp://hdl.handle.net/10637/15968-
dc.description.abstractFor the first time in the literature, duckweed (Lemna minor) tolerance (alone or in combination with a consortium of bacteria) to spent metal-working fluid (MWF) was assessed, together with its capacity to reduce the chemical oxygen demand (COD) of this residue. In a preliminary study, L. minor response to pre-treated MWF residue (ptMWF) and vacuum-distilled MWF water (MWFw) was tested. Plants were able to grow in both residues at different COD levels tested (up to 2300 mg·l−1), showing few toxicity symptoms (mainly growth inhibition). Plant response to MWFw was more regular and dose responsive than when exposed to ptMWF. Moreover, COD reduction was less significant in ptMWF. Thus, based on these preliminary results, a second study was conducted using MWFw to test the effectiveness of inoculation with a bacterial consortium isolated from a membrane bioreactor fed with the same residue. After 5 days of exposure, COD in solutions containing inoculated plants was significantly lower than in non-inoculated ones. Moreover, inoculation reduced β+γ-tocopherol levels in MWFw-exposed plants, suggesting pollutant imposed stress was reduced. We therefore conclude from that L. minor is highly tolerant to spent MWF residues and that this species can be very useful, together with the appropriate bacterial consortium, in reducing COD of this residue under local legislation limits and thus minimise its potential environmental impact. Interestingly, the lipophilic antioxidant tocopherol (especially the sum of β+γ isomers) proved to be an effective plant biomarker of pollution.en_EN
dc.formatapplication/pdf-
dc.language.isoen-
dc.publisherWiley-
dc.relation.ispartofPlant Biology-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es-
dc.rightsOpen Access-
dc.subjectLentejas de aguaes_ES
dc.subjectPigmentos fotosintéticoses_ES
dc.subjectVitamina Ees_ES
dc.titleLemna minor tolerance to metal-working fluid residues: implications for rhizoremediationes_ES
dc.typeArtículoes_ES
dc.identifier.doi10.1111/plb.12454-
dc.relation.projectIDComunidad de Madrid (Grants S-0505/AMB/0321 and S-2009/AMB/1511-
dc.relation.projectIDMicroambiente- CM), by the Spanish Ministry of Science and Innovation (Grant CGL2010- 15675, sub-programme BOS)-
dc.centroUniversidad San Pablo-CEU-
Aparece en las colecciones: Facultad de Farmacia




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.