Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/15728

Effect of wheat straw ash as cementitious material on the mechanical characteristics and embodied carbon of concrete reinforced with coir fiber


Vista previa

Ver/Abrir:
 Effect_Bheel_et_al_Heliyon_2024.pdf

3,26 MB
Adobe PDF
Título : Effect of wheat straw ash as cementitious material on the mechanical characteristics and embodied carbon of concrete reinforced with coir fiber
Autor : Bheel, Naraindas
Kumar, Sandeep
Serkan Kirgiz, Mehmet
Ali, Mohsin
Almujibah, Hamad R.
Ahmad, Mahmood
González Lezcano, Roberto Alonso.
Materias: Cementitious materialMechanical characteristics
Editorial : Elsevier
Citación : Bheel, N., Kumar, S., Kirgiz, M. S., Ali, M., Almujibah, H. R., Ahmad, M., & Gonzalez-Lezcano, R. A. (2024). Effect of wheat straw ash as cementitious material on the mechanical characteristics and embodied carbon of concrete reinforced with coir fiber. Heliyon, 10(2). doi 10.1016/j.heliyon.2024.e24313
Resumen : The use of supplementary cementitious materials has been widely accepted due to increasing global carbon emissions resulting from demand and the consequent production of Portland cement. Moreover, researchers are also working on complementing the strength deficiencies of concrete; fiber reinforcement is one of those techniques. This study aims to assess the influence of recycling wheat straw ash (WSA) as cement replacement material and coir/coconut fibers (CF) as reinforcement ingredients together on the mechanical properties, permeability and embodied carbon of concrete. A total of 255 concrete samples were prepared with 1:1.5:3 mix proportions at 0.52 water-cement ratio and these all-concrete specimens were cured for 28 days. It was revealed that the addition of 10 % WSA and 2 % CF in concrete were recorded the compressive, splitting tensile and flexural strengths by 33 MPa, 3.55 MPa and 5.16 MPa which is greater than control mix concrete at 28 days respectively. Moreover, it was also observed that the permeability of concrete incorporating 4 % of coir fiber and 20 % of WSA was reduced by 63.40 % than that of the control mix after 28 days which can prevent the propagation of major and minor cracks. In addition, the embodied carbon of concrete is getting reduced when the replacement level of cement with WSA along with CF increases in concrete. Furthermore, based on the results obtained, the optimum amount of WSA was suggested to be 10 % and that of coir fiber reinforcement was suggested to be 2 % for improved results.
URI : http://hdl.handle.net/10637/15728
Derechos: http://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
Open Access
ISSN : 2405-8440
Fecha de publicación : 11-ene-2024
Centro : Universidad San Pablo-CEU
Aparece en las colecciones: Escuela de Politécnica Superior





Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.