Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/15104
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUniversidad San Pablo-CEU. Escuela Politécnica Superior. Departamento de Tecnologías de la Información-
dc.contributor.otherGrupo: Laboratorio de Ingeniería Biomédica (Biomedical Engineering Laboratory) (BIOLAB)-
dc.creatorRaya López, Rafael-
dc.creatorGarcía Carmona, Rodrigo-
dc.creatorSánchez López de Pablo, Cristina-
dc.creatorUrendes, Eloy-
dc.creatorRamírez, Oscar-
dc.creatorMartín, Álvaro-
dc.creatorOtero Quintana, Abraham-
dc.date2018-
dc.date.accessioned2024-01-24T15:48:26Z-
dc.date.available2024-01-24T15:48:26Z-
dc.date.issued2018-08-07-
dc.identifier.citationRaya R, Garcia-Carmona R, Sanchez C, Urendes E, Ramirez O, Martin A, Otero A. An Inexpensive and Easy to Use Cervical Range of Motion Measurement Solution Using Inertial Sensors. Sensors. 2018; 18(8):2582. https://doi.org/10.3390/s18082582-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/10637/15104-
dc.description.abstractNeck injuries and the related pain have a high prevalence and represent an important health problem. To properly diagnose and treat them, practitioners need an accurate system for measuring Cervical Range Of Motion (CROM). This article describes the development and validation of an inexpensive, small (4 cm 4 cm 8 cm), light (< 200 g) and easy to use solution for measuring CROM using wearable inertial sensors. The proposed solution has been designed with the clinical practice in mind, after consulting with practitioners. It is composed of: (a) two wearable wireless MEMS-based inertial devices, (b) a recording and report generation software application and (c) a measurement protocol for assessing CROM. The solution provides accurate (none of our results is outside the ROM ranges when compared with previously published results based on an optical tracking device) and reliable measurements (ICC = 0.93 for interrater reliability when compared with an optical tracking device and ICC > 0.90 for test-retest reliability), surpassing the popular CROM instrument’s capabilities and precision. It also fulfills the needs for clinical practice attending to effectiveness, efficiency (4 min from setup to final report) and user’s satisfaction (as reported by practitioners). The solution has been certified for mass-production and use in medical environments.en_EN
dc.language.isoenes_ES
dc.publisherMDPI-
dc.relation.ispartofSensors-
dc.rightsOpenAccess-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es-
dc.subjectCROMen_EN
dc.subjectInertial sensoren_EN
dc.subjectWearable sensoren_EN
dc.subjectNeck painen_EN
dc.subjectDiagnosisen_EN
dc.subjectAssessmenten_EN
dc.titleAn Inexpensive and Easy to Use Cervical Range of Motion Measurement Solution Using Inertial Sensorsen_EN
dc.typeArtículoes_ES
dc.typeArtículo-
dc.identifier.doi10.3390/s18082582-
dc.relation.projectIDUniversidad San Pablo CEU and Banco Santander, under the grant “IV Convocatoria de Ayudas a grupos de investigación precompetitivos”-
dc.relation.projectIDCentro para el Desarrollo Tecnológico Industrial (CDTI) under the grant “Ayudas destinadas a nuevos proyectos empresariales de empresas innovadoras (Programa NEOTEC) de la Convocatoria del año 2015”-
Aparece en las colecciones: Escuela de Politécnica Superior




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.