Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/14927
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUniversidad San Pablo-CEU. Facultad de Medicina. Departamento de Enfermería y Fisioterapia-
dc.contributor.otherGrupo: Valoración y tratamiento de las alteraciones del control sensoriomotor (FisioMov)-
dc.creatorBocos Corredor, Elena-
dc.creatorPérez Fernández, Tomás-
dc.creatorPerez Domínguez, Raquel-
dc.creatorLiébana Sánchez-Toscano, Sonia-
dc.creatorArmijo Olivo, Susan-
dc.creatorRaya López, Rafael-
dc.creatorMartin-Pintado Zugasti, Aitor-
dc.date.accessioned2024-01-17T14:15:06Z-
dc.date.available2024-01-17T14:15:06Z-
dc.date.issued2023-04-12-
dc.identifier.citationBocos-Corredor E, Pérez-Fernández T, Perez-Dominguez R, Liébana S, Armijo-Olivo S, Raya R, Martin-Pintado-Zugasti A. Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test. Sensors (Basel). 2023 Apr 12;23(8):3911. doi: 10.3390/s23083911. PMID: 37112252; PMCID: PMC10141233.-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/10637/14927-
dc.description.abstractThe aim of the study was to develop a novel real-time, computer-based synchronization system to continuously record pressure and craniocervical flexion ROM (range of motion) during the CCFT (craniocervical flexion test) in order to assess its feasibility for measuring and discriminating the values of ROM between different pressure levels. This was a descriptive, observational, crosssectional, feasibility study. Participants performed a full-range craniocervical flexion and the CCFT. During the CCFT, a pressure sensor and a wireless inertial sensor simultaneously registered data of pressure and ROM. A web application was developed using HTML and NodeJS technologies. Forty-five participants successfully finished the study protocol (20 males, 25 females; 32 (11.48) years). ANOVAs showed large effect significant interactions between pressure levels and the percentage of full craniocervical flexion ROM when considering the 6 pressure reference levels of the CCFT (p < 0.001; 2 = 0.697), 11 pressure levels separated by 1 mmHg (p < 0.001; 2 = 0.683), and 21 pressure levels separated by 0.5 mmHg (p < 0.001; 2 = 0.671). The novel time synchronizing system seems a feasible option to provide real-time monitoring of both pressure and ROM, which could serve as reference targets to further investigate the potential use of inertial sensor technology to assess or train deep cervical flexors.en_EN
dc.language.isoen-
dc.publisherMDPI-
dc.relation.ispartofSensors-
dc.rightshttp://creativecommons.org/licenses/by/4.0/deed.es-
dc.subjectAssessment technologyen_EN
dc.subjectBiomechanics feasibility studiesen_EN
dc.subjectMovement disordersen_EN
dc.subjectNeck painen_EN
dc.titlePotential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Testen_EN
dc.typeArtículoen_EN
dc.identifier.doi10.3390/s23083911-
dc.relation.projectIDAgencia Estatal de Investigación, SpanishMinistry of Science-
dc.centroUniversidad San Pablo-CEU-
Aparece en las colecciones: Fisioterapia




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.