Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10637/14897
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.other | UCH. Departamento de Ciencias Biomédicas | - |
dc.creator | Escudero Ortiz, Vanesa | - |
dc.creator | Pérez Ruixo, Juan José | - |
dc.creator | Valenzuela, Belén | - |
dc.date.accessioned | 2024-01-16T13:06:00Z | - |
dc.date.available | 2024-01-16T13:06:00Z | - |
dc.date.issued | 2015-04 | - |
dc.identifier.citation | Escudero-Ortiz, V., Pérez-Ruixo, J.J. & Valenzuela, B. (2015). Development and validation of an HPLC-UV method for pazopanib quantification in human plasma and application to patients with cancer in routine clinical practice. Therapeutic Drug Monitoring, vol. 37, i. 2 (apr.), pp. 172–179. DOI: https://doi.org/10.1097/FTD.0000000000000121 | es_ES |
dc.identifier.issn | 0163-4356 | - |
dc.identifier.issn | 1536-3694 (Electrónico) | - |
dc.identifier.uri | http://hdl.handle.net/10637/14897 | - |
dc.description | Este recurso no está disponible en acceso abierto por política de la editorial. | - |
dc.description.abstract | Background: Pazopanib, a new oral angiogenesis inhibitor, has demonstrated clinical activity against multiple solid tumors and was approved for the treatment of patients with advanced renal cell carcinoma. As an exposure-response relationship has been observed for pazopanib, its therapeutic drug monitoring could be a valuable tool in clinical practice. Therefore, the aim of this study was to develop and validate a selective and precise high performance liquid chromatography-ultraviolet method for the measurement of pazopanib in plasma from patients with cancer. Methods: After liquid-liquid extraction with diethyl ether, pazopanib and gefitinib (internal standard) were separated using isocratic elution on an Ultrabase C18 column using a mobile phase consisting of a mixture in vol/vol proportion of 47:53 of ammonium acetate (pH, 7; 0.02 mol/L) and acetonitrile/methanol (70:30, vol/vol) pumped at a constant flow rate of 1 mL/min. Quantification was performed at 260 nm. Method validation was undertaken as per the guidelines for Bioanalytical Method Validation published by the Food and Drug Administration and European Medicines Agency. Results: Calibration curves were linear over the range 0.5-100 mcg/mL. Interday and intraday coefficients of variations were less than 4.5%. The limit of detection and the lower limit of quantification were 0.2 and 0.5 mcg/mL, respectively. Recovery of pazopanib from plasma was >80%. Conclusions: This is the first high performance liquid chromatography-ultraviolet method for pazopanib quantification that has been validated within a wide range of plasma concentrations and is a suitable method for therapeutic drug monitoring of pazopanib. | es_ES |
dc.language.iso | en | es_ES |
dc.publisher | Wolters Kluwer | es_ES |
dc.relation.ispartof | Therapeutic Drug Monitoring, vol. 37, i. 2 (apr.) | - |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | - |
dc.subject | Cáncer | - |
dc.subject | Cancer | - |
dc.subject | Medicamento | - |
dc.subject | Drugs | - |
dc.subject | Tratamiento médico | - |
dc.subject | Medical treatment | - |
dc.title | Development and validation of an HPLC-UV method for pazopanib quantification in human plasma and application to patients with cancer in routine clinical practice | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | https://doi.org/10.1097/FTD.0000000000000121 | - |
dc.centro | Universidad Cardenal Herrera-CEU | - |
Aparece en las colecciones: | Dpto. Ciencias Biomédicas |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.