Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/14664
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUniversidad San Pablo-CEU. Escuela Politécnica Superior-
dc.creatorGonzález Lezcano, Roberto Alonso.-
dc.creatorSanglier Contreras, Gastón-
dc.creatorIglesias Sanz, Carlos Miguel-
dc.creatorLópez Fernández, Eduardo José-
dc.date.accessioned2023-10-27T11:32:26Z-
dc.date.available2023-10-27T11:32:26Z-
dc.date.issued2023-09-13-
dc.identifier.citationGonzález-Lezcano RA, Sanglier Contreras G, Iglesias Sanz CM, Sancho Alambillaga R and López Fernández EJ (2023), Construction parameters that affect the air leaks of the envelope in dwellings in Madrid. Front. Built Environ. 9:1220559. doi: 10.3389/fbuil.2023.1220559es_ES
dc.identifier.issn2297-3362-
dc.identifier.urihttp://hdl.handle.net/10637/14664-
dc.description.abstractIn buildings, ventilation, or rather, a lack of airtightness facilitates air leaks, from the outside to the inside and vice versa, and is not controlled. Cold air enters through the enclosure, and warm air is lost to the outdoors, due to the poor hermeticity of the facades, roofs, carpentry, ducts, etc. In order to quantify the airtightness in multi-family dwellings in Madrid, 151 blower door tests have been carried out in multi-family dwellings built in different periods whose execution has been regulated by the UNE-EN 13829 standard. Through its quantification by an n50 value, the average values of 5.8 renovations per hour have been obtained in addition to detecting the main points where air infiltration occurs. The constant improvement in the transmittance of construction elements has indicated that the entry of outside air has a progressively greater relevance to the total energy consumed by the residential sector while facilitating the uncontrolled movement of air through the building envelope. This not only implies higher energy consumption but also generates a series of problems that affect the health of the occupants, such as a lack of thermal comfort, entry of pollutants and odours, noise, inadequate operation of ventilation systems, and less protection against fire.es_ES
dc.formatapplication/pdf-
dc.language.isoenes_ES
dc.publisherFrontiers Mediaes_ES
dc.relation.ispartofFrontiers in Built Environment-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es-
dc.rightsOpenAccess-
dc.subjectResidential buildingsen_EN
dc.subjectNatural ventilationen_EN
dc.subjectAir infiltrationen_EN
dc.subjectBuilding envelope airtightnessen_EN
dc.subjectEnergy leakageen_EN
dc.subjectIndoor air quality monitoringen_EN
dc.titleConstruction parameters that affect the air leaks of the envelope in dwellings in Madriden_EN
dc.typeArtículo-
dc.identifier.doi10.3389/fbuil.2023.1220559-
dc.relation.projectIDGIMIDyL Research Group. Project Ref. G20/6-04-
dc.centroUniversidad San Pablo-CEU-
Aparece en las colecciones: Escuela de Politécnica Superior