Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/14601
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUniversidad San Pablo-CEU. Escuela Politécnica Superior-
dc.creatorFeijó Muñoz, Jesús-
dc.creatorPoza-Casado, Irene-
dc.creatorGonzález Lezcano, Roberto Alonso.-
dc.creatorPardal March, Cristina-
dc.creatorEcharri, Víctor-
dc.creatorAssiego de Larriva, Rafael-
dc.creatorFernández-Agüera, J.-
dc.creatorDios-Viéitez, María Jesús-
dc.creatorDel Campo-Díaz, Víctor José-
dc.creatorMontesdeoca Calderín, Manuel-
dc.creatorPadilla Marcos, Miguel Ángel-
dc.creatorMeiss, Alberto-
dc.date2018-
dc.date.accessioned2023-09-16T04:00:22Z-
dc.date.available2023-09-16T04:00:22Z-
dc.date.issued2018-03-21-
dc.identifier000000741555-
dc.identifier.citationFeijó-Muñoz, J.; Poza-Casado, I.; González-Lezcano, R.A.; Pardal, C.; Echarri, V.; Assiego De Larriva, R.; Fernández-Agüera, J.; Dios-Viéitez, M.J.; Del Campo-Díaz, V.J.; Montesdeoca Calderín, M.; et al. Methodology for the Study of the Envelope Airtightness of Residential Buildings in Spain: A Case Study. Energies 2018, 11, 704. https://doi.org/10.3390/en11040704-
dc.identifier.issn1996-1073-
dc.identifier.urihttp://hdl.handle.net/10637/14601-
dc.description.abstractAir leakage and its impact on the energy performance of dwellings has been broadly studied in countries with cold climates in Europe, US, and Canada. However, there is a lack of knowledge in this field in Mediterranean countries. Current Spanish building regulations establish ventilation rates based on ideal airtight envelopes, causing problems of over-ventilation and substantial energy losses. The aim of this paper is to develop a methodology that allows the characterization of the envelope of the housing stock in Spain in order to adjust ventilation rates taking into consideration air leakage. A methodology that is easily applicable to other countries that consider studying the airtightness of the envelope and its energetic behaviour improvement is proposed. A statistical sampling method has been established to determine the dwellings to be tested, considering relevant variables concerning airtightness: climate zone, year of construction, and typology. The air leakage rate is determined using a standardized building pressurization technique according to European Standard EN 13829. A representative case study has been presented as an example of the implementation of the designed methodology and results are compared to preliminary values obtained from the database.en_EN
dc.formatapplication/pdf-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.ispartofEnergies-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es-
dc.rightsOpenAccess-
dc.subjectResidential buildingsen_EN
dc.subjectInfiltrationsen_EN
dc.titleMethodology for the Study of the Envelope Airtightness of Residential Buildings in Spainen_EN
dc.typeArtículo-
dc.identifier.doi10.3390/en11040704-
dc.centroUniversidad San Pablo-CEU-
Aparece en las colecciones: Escuela de Politécnica Superior




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.