Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/14592
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUniversidad San Pablo-CEU. Escuela Politécnica Superior-
dc.creatorMoreno Santamaria, Belén-
dc.creatorDel Ama Gonzalo, Fernando-
dc.creatorPinette, Danielle-
dc.creatorGonzález Lezcano, Roberto Alonso.-
dc.creatorLauret Aguirregabiria, Benito-
dc.creatorHernández Ramos, Juan Antonio-
dc.date2020-
dc.date.accessioned2023-09-15T04:00:19Z-
dc.date.available2023-09-15T04:00:19Z-
dc.date.issued2020-06-19-
dc.identifier000000741489-
dc.identifier.citationMoreno Santamaria, B.; del Ama Gonzalo, F.; Pinette, D.; Gonzalez-Lezcano, R.-A.; Lauret Aguirregabiria, B.; Hernandez Ramos, J.A. Application and Validation of a Dynamic Energy Simulation Tool: A Case Study with Water Flow Glazing Envelope. Energies 2020, 13, 3203. https://doi.org/10.3390/en13123203-
dc.identifier.issn1996-1073-
dc.identifier.urihttp://hdl.handle.net/10637/14592-
dc.description.abstractThe transparent materials used in building envelopes significantly contribute to heating and cooling loads of a building. The use of transparent materials requires to solve issues regarding heat gain, heat loss, and daylight. Water flow glazing (WFG), a disruptive technology, includes glazing as part of the Heating, Ventilation and Air Conditioning (HVAC) system. Water is transparent to visible wavelengths, but it captures most of the infrared solar radiation. As an alternative to fossil fuel-based HVAC systems, the absorbed energy can be transferred to the ground through borehole heat exchangers and dissipated as a means of free-cooling. Researchers of the Polytechnic University of Madrid have developed a software tool to calculate the energy balance while incorporating the dynamic properties of WFG. This article has studied the mathematical model of that tool and validated its ability to predict energy savings in buildings, taking spectral and thermal parameters of glazing catalogs, commercial software, and inputs from the measurements of the prototypes. The results found in this article showed that it is possible to predict the thermal behavior of WFG and the energy savings by comparing the thermal parameters of two prototypes. The energy absorbed by the water depends on the mass flow rate and the inlet and outlet temperatures.en_EN
dc.formatapplication/pdf-
dc.language.isosp-
dc.publisherMDPI-
dc.relation.ispartofEnergies-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.es-
dc.subjectWater flow glazingen_EN
dc.subjectBuilding energy simulationen_EN
dc.subjectExperimental validationen_EN
dc.titleApplication and Validation of a Dynamic Energy Simulation Tool: A Case Study with Water Flow Glazing Envelopeen_EN
dc.typeArtículo-
dc.identifier.doi10.3390/en13123203-
dc.relation.projectIDProject CEU-Banco Santander (Ref: MVP19V14)-
dc.relation.projectIDKSC Faculty Development Grant-
dc.centroUniversidad San Pablo-CEU-
Aparece en las colecciones: Escuela de Politécnica Superior




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.