Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/14401
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUCH. Departamento de Proyectos, Teoría y Técnica del Diseño y la Arquitectura-
dc.contributor.otherProducción Científica UCH 2022-
dc.creatorTur Lahiguera, Carles-
dc.creatorPlá Mora, Ignacio-
dc.creatorArgilés Herrero, Rafael-
dc.creatorSalvador Herranz, Gustavo-
dc.creatorAlmenar Gil, David-
dc.date2022-
dc.date.accessioned2023-06-04T04:01:25Z-
dc.date.available2023-06-04T04:01:25Z-
dc.date.issued2022-02-09-
dc.identifier.citationTur, C., Plá, I., Argilés-Herrero, R., Salvador-Herranz, G. & Almenar, D. (2022). All-in-one mosquito containers: from the laboratory to the release sites. Insects, vol. 13, i. 2 (09 feb.), art. 178. DOI: https://doi.org/10.3390/insects13020178-
dc.identifier.issn2075-4450 (Electrónico)-
dc.identifier.urihttp://hdl.handle.net/10637/14401-
dc.descriptionEste artículo se encuentra disponible en la siguiente URL: https://www.mdpi.com/2075-4450/13/2/178-
dc.descriptionEste artículo de investigación pertenece al número especial "Mosquito Handling, Transport, Release and Male Trapping Methods".-
dc.description.abstractIntegrated vector control programs that use a Sterile Insect Technique approach require the production and release of large numbers of high quality, sterile male insects. In pilot projects conducted worldwide, sterile males are usually kept in containers at low densities until their manual release on the ground. Although the quality of the released insects is high, these containers are only suitable for small-scale projects, given the fact that the manual labor required for release is significant and therefore untenable in large-scale projects. This study will compare and contrast the quality of the males reared in the proposed “all-in-one” containers which considerably reduce both the handling of the insects and the manual labor required for release. As a result, project costs are lower. The design of these “all-in-one” containers incorporates two important features: ventilation and the density of the vertical resting surface. Having evaluated both features, it can be concluded that ventilation does not directly affect the quality of the insects, at least in the range of dimensions tested. However, the quality of the male insects is reduced in relation to an increase in the number of mosquitoes, with 500 being the optimum quantity of mosquitoes per “all-in-one” container.-
dc.formatapplication/pdf-
dc.languagees-
dc.language.isoen-
dc.publisherMDPI-
dc.relationEste artículo de investigación ha sido financiado por la Conselleria de Agricultura, Desarrollo Rural, Emergencia Climática y Transición Ecológica y por la Subdirección de Innovación y Desarrollo de Servicios (TRAGSA).-
dc.relation.ispartofInsects, vol. 13, i. 2 (09 feb. 2022)-
dc.rightshttp://creativecommons.org/licenses/by/4.0/deed.es-
dc.subjectCulícidos - Genética - Control.-
dc.subjectCulícidos - Cría y explotación.-
dc.subjectMosquitoes - Breeding.-
dc.subjectMosquitoes - Genetics - Control.-
dc.titleAll-in-one mosquito containers from the laboratory to the release sites-
dc.typeArtículo-
dc.identifier.doihttps://doi.org/10.3390/insects13020178-
dc.centroUniversidad Cardenal Herrera-CEU-
Aparece en las colecciones: Dpto. Proyectos, Teoría y Técnica del Diseño y la Arquitectura




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.