Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10637/10529
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.otherUCH. Departamento de Fisioterapia (Extinguido)-
dc.contributor.otherProducción Científica UCH 2018-
dc.contributor.otherUCH. Departamento de Enfermería y Fisioterapia-
dc.creatorOrtega Pérez de Villar, Lucíaes
dc.creatorMartínez Olmos, Francisco Josées
dc.creatorJunqué Jiménez, Annaes
dc.creatorAmer Cuenca, Juan Josées
dc.creatorMartínez Gramage, Javieres
dc.creatorMercer, Tomes
dc.creatorSegura Ortí, Evaes
dc.date2018es
dc.date.accessioned2019-07-09T12:30:43Z-
dc.date.available2019-07-09T12:30:43Z-
dc.date.issued2018-08-22-
dc.identifier.citationOrtega Pérez del Villar, L., Martínez Olmos, FJ., Junqué Jiménez, A., Amer Cuenca, JJ., Martínez Gramage, J., Mercer, T. et al. (2018). Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis. PLoS ONE, vol. 13 (august), n. 8, art. e0201035. DOI: https://doi.org/10.1371/journal.pone.0201035-
dc.identifier.issn1932-6203.-
dc.identifier.urihttp://hdl.handle.net/10637/10529-
dc.descriptionEste artículo se encuentra disponible en la página web de la revista en la siguiente URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0201035es
dc.description.abstractFunctional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the relative and the absolute reliability of the Short Physical Performance Battery (SPPB), One-Legged Stance Test (OLST), and Timed Up and Go (TUG) test, as well as the minimal detectable change (MDC) scores for these tests in CKD patients receiving HD. Seventy-one end-stage CKD patients receiving HD therapy, aged between 21 and 90 years, participated in the study. The patients completed two testing sessions one to two weeks apart and performed by the same examiner, comprising the following tests: the SPPB (n = 65), OLST (n = 62), and TUG test (n = 66). High intraclass correlation coefficients ( 0.90) were found for all the tests, suggesting that their relative reliability is excellent. The MDC scores for the 90% confidence intervals were as follows: 1.7 points for the SPPB, 11.3 seconds for the OLST, and 2.9 seconds for the TUG test. The reliability of the SPPB, OLST, and TUG test for this sample were all considered to be acceptable. The MDC data generated by these tests can be used to monitor meaningful changes in the functional capacity of the daily living-related activity of CKD patients on HD.-
dc.formatapplication/pdfes
dc.language.isoenes
dc.publisherPLOS.-
dc.relationEste artículo ha sido financiado por la Universidad CEU Cardenal Herrera a través de las “Ayudas para la realización de proyectos de Investigación+Docencia en la CEU-UCH 2017-2018” con código de proyecto IDOC17/19.-
dc.relationFinanciación Universidad-
dc.relation.ispartofPLoS ONE, vol. 13 (august 2018), n. 8.-
dc.rightshttp://creativecommons.org/licenses/by/4.0/deed.eses
dc.subjectKidneys - Diseases - Patients - Treatment.es
dc.subjectRiñones - Enfermedades - Pacientes - Tratamiento.es
dc.subjectInsuficiencia renal crónica - Pacientes - Tratamiento.es
dc.subjectChronic renal failure - Patients - Treatment.es
dc.subjectInsuficiencia renal crónica - Pacientes - Evaluación funcional.es
dc.subjectHemodialysis.es
dc.subjectRiñones - Enfermedades - Pacientes - Evaluación funcional.es
dc.subjectChronic renal failure - Patients - Functional assessment.es
dc.subjectKidneys - Diseases - Patients - Functional assessment.es
dc.subjectHemodiálisis.es
dc.titleTest-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysises
dc.typeArtículoes
europeana.dataProviderUNIVERSIDAD SAN PABLO CEU-
europeana.isShownAthttp://hdl.handle.net/10637/10221-
europeana.objecthttp://repositorioinstitucional.ceu.es/visor/libros/709542/thumb_europeana/709542.jpg-
europeana.providerHispana-
europeana.rightshttp://creativecommons.org/publicdomain/zero/1.0/-
europeana.typeTEXT-
dc.identifier.doihttps://doi.org/10.1371/journal.pone.0201035-
dc.relation.projectIDIDOC17/19-
dc.centroUniversidad Cardenal Herrera-CEU-
Aparece en las colecciones: Dpto. Enfermería y Fisioterapia




Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.