Assessment of indoor air quality and comfort by comparing an energy simulation and actual data in Native American shelters

dc.centroUniversidad San Pablo-CEU
dc.contributor.authorFowler, Paul
dc.contributor.authorDel Ama Gonzalo, Fernando
dc.contributor.authorNewell, Sarah
dc.contributor.authorPoolman, James
dc.contributor.authorMontero Burgos, María Jesús
dc.contributor.authorGonzález Lezcano, Roberto Alonso
dc.contributor.otherUniversidad San Pablo-CEU. Escuela Politécnica Superior
dc.date.accessioned2023-10-27T15:02:44Z
dc.date.available2023-10-27T15:02:44Z
dc.date.issued2023-05-24
dc.description.abstractIntroduction: This research will determine if a native American shelter (wigwam) can create comfort and if while doing so can provide healthy indoor air quality (IAQ) levels as defined by current standards. Concurrent to this research a technique to digitally model the outcomes of comfort created within the shelter was developed. Methods: A fullsize example of a wigwam was built and data from inside and outside the wigwam monitored for comparison. Data collected both inside and outside was temperature and relative humidity of the air, collected inside the wigwam were CO2, VOC, and PM2.5 levels. The wigwam allowed us to compare the accuracy of a digital model created in Design Builder. The Design Builder model was made to the specific size, materials, and location of the actual wigwam. This allowed an accurate comparison of temperature and relative humidity levels. Design-Builder accurately recreated the attributes of the full-size wigwam. Results and Discussion: It was found that comfort can be achieved to modern standards in this native shelter; as temperature, relative humidity, and rainfall exposure can all be controlled to acceptable levels. Indoor air quality is always at an acceptable level when a fire isn’t active. When an open fire is introduced, the particulates and VOC released into the interior of the wigwam are at dangerous levels. A woodstove with flue pipe allowed for comfort to be maintained at healthier air quality levels but did not reach acceptable levels for particulate matter.en_EN
dc.formatapplication/pdf
dc.identifier.citationFowler P, Del Ama Gonzalo F, Newell S, Poolman J, Montero Burgos MJ and González Lezcano RA (2023), Assessment of indoor air quality and comfort by comparing an energy simulation and actual data in Native American shelters. Front. Built Environ. 9:1202965. doi: 10.3389/fbuil.2023.1202965es_ES
dc.identifier.doi10.3389/fbuil.2023.1202965
dc.identifier.issn2297-3362
dc.identifier.urihttp://hdl.handle.net/10637/14670
dc.language.isoen
dc.publisherFrontiers Mediaes_ES
dc.relation.ispartofFrontiers in Built Environment
dc.rightsopen access
dc.rights.cchttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectHative American shelteres_ES
dc.subjectIndoor air quality (IAQ)es_ES
dc.subjectBuilding energy simulationes_ES
dc.subjectBuilding environmentes_ES
dc.subjectMonitoringes_ES
dc.titleAssessment of indoor air quality and comfort by comparing an energy simulation and actual data in Native American shelterses_ES
dc.typeArtículoes_ES
dspace.entity.typePublicationes
relation.isAuthorOfPublication1bee1d5c-eeff-48aa-88e2-3dfb50a298f9
relation.isAuthorOfPublication0bf10684-dc78-4898-aec0-5037ee0a105e
relation.isAuthorOfPublication.latestForDiscovery1bee1d5c-eeff-48aa-88e2-3dfb50a298f9

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Assessment_Fowler_et_al_Fro_Built_Env_2023.pdf
Size:
3.79 MB
Format:
Adobe Portable Document Format
Description: